BBakken SubsurfaceNorth Dakota well index

Spacing unit · McKenzie County

1,280-acre Bakken spacing unit

T153N R97W sections 30, 31

Spacing unit8 wells allowed · order 31430Banks-Bakken

Unit facts

Formation
Bakken
Acres
1,280
Type
Spacing unit
Land described
T153N R97W sections 30, 31
Pool
Banks-Bakken
Zone
Zone VII
County
McKenzie County
Surveyed wells inside
7
Most wells operated by
Devon Energy
Unit id
dsu-e2d5844e7f462229ed4f
Wells allowed by the latest linked order
8
Wells assigned to this unit
7
Pending permits inside
0
Balance under the allowance
+1
First linked order
Apr 22, 2010
Laterals that still fit (Nov 2026 method)
3 (2.85 two-mile equivalents)
Neighbourhood target density
9.62 two-mile laterals per 1,280 acres
Density drilled so far
6.51 per 1,280 acres

Room to drill: 3 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

BRODERSON 30-31 3HBRODERSON 30-31 4TFHBRODERSON 30-31F #7HBRODERSON 30-31 2HBRODERSON 30-31F #5HBRODERSON 30-31F #8TFHBRODERSON 30-31 #1TFH1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
BRODERSON 30-31 3HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,282 ft100%
BRODERSON 30-31 4TFHDEVON ENERGY WILLISTON, L.L.C.Active (A)10,169 ft100%
BRODERSON 30-31F #7HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,767 ft100%
BRODERSON 30-31 2HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,748 ft100%
BRODERSON 30-31F #5HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,654 ft100%
BRODERSON 30-31F #8TFHDEVON ENERGY WILLISTON, L.L.C.Active (A)9,616 ft100%
BRODERSON 30-31 #1TFHDEVON ENERGY WILLISTON, L.L.C.Active (A)9,466 ft100%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 14554Case 12302Established the spacing unit, 1 well allowedPANTHER ENERGY CO., LLC
  2. Order 14369Case 12119Designated the spacing unitTRACKER RESOURCE DEVELOPMENT II, LLC
  3. Order 15122Case 12855Designated the spacing unitCONTINENTAL RESOURCES, INC.
  4. Order 16143Case 13859Designated the spacing unit, 4 wells allowedBRIGHAM OIL & GAS, L.P.
  5. Order 16281Case 14006Established the spacing unit, 4 wells allowed
  6. Order 16939Case 14661Pooled all interests in the unitBRIGHAM OIL & GAS, L.P.
  7. Order 16777Case 14500Designated the spacing unit, 7 wells allowedKODIAK OIL & GAS (USA) INC.
  8. Order 16892Case 14614Established the spacing unit, 7 wells allowedCONTINENTAL RESOURCES, INC.
  9. Order 19276Case 17008Designated the spacing unit, 7 wells allowedNEWFIELD PRODUCTION CO.
  10. Order 18900Case 16631Designated the spacing unit, 8 wells allowedKODIAK OIL & GAS (USA) INC.
  11. Order 19462Case 17193Designated the spacing unit, 8 wells allowedCONTINENTAL RESOURCES, INC.
  12. Order 19521Case 17252Established the spacing unit, 8 wells allowedBRIGHAM OIL & GAS, L.P.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

One other unit shares a surveyed well with this one; overlapping units are not additive.