Spacing unit · McKenzie County
1,280-acre Bakken spacing unit
T152N R104W sections 21, 28
Unit facts
- Formation
- Bakken
- Acres
- 1,280
- Type
- Spacing unit
- Land described
- T152N R104W sections 21, 28
- Pool
- Briar Creek-Bakken
- Zone
- Zone III
- County
- McKenzie County
- Surveyed wells inside
- 11
- Most wells operated by
- Devon Energy
- Unit id
dsu-e3b97a3fb8e652744eff- Wells allowed by the latest linked order
- 6
- Wells assigned to this unit
- 1
- Pending permits inside
- 0
- Balance under the allowance
- -4
- First linked order
- Apr 28, 2011
- Laterals that still fit (Nov 2026 method)
- 0
- Neighbourhood target density
- 4.22 two-mile laterals per 1,280 acres
- Density drilled so far
- 5.55 per 1,280 acres
Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.
Map
DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.
Wells inside the unit
| Well | Operator | Status | Lateral inside |
|---|---|---|---|
| STUBBS 28-21 1H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 11,019 ft100% |
| NILES 19-22F 1H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 5,337 ft31% |
| NILES 19-22F 2H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 5,332 ft31% |
| NILES 19-22F 3H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 5,326 ft28% |
| NILES 19-22F 4H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 5,322 ft30% |
| HOPES 30-27F 1H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 5,315 ft30% |
| HOPES 30-27F 2H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 5,311 ft31% |
| HOPES 30-27F 3H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 5,305 ft31% |
| HOPES 30-27F 4H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 5,302 ft31% |
| HOPES 30-27F 5H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 5,296 ft31% |
| SAKAKAWEA 1-21H | Zavanna Energy Operating, LLC | Plugged and abandoned (PA) | 4,940 ft100% |
Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.
Order history
- Order 15716Case 13438Established the spacing unit, 1 well allowed
- Order 15716Case 13438Designated the spacing unit
- Order 19420Case 17152Pooled all interests in the unitBRIGHAM OIL & GAS, L.P.
- Order 17380Case 15132Designated the spacing unit, 8 wells allowedBRIGHAM OIL & GAS, LP
- Order 20405Case 18136Established the spacing unit, 8 wells allowedBRIGHAM OIL & GAS, LP
- Order 21991Case 19685Established the spacing unit, 1 well allowedBRIGHAM OIL & GAS, LP
- Order 22887Case 20581Listed the unit in a pool zone table, 6 wells allowedZAVANNA, LLC
- Order 34201Case 31480Designated the spacing unitDEVON ENERGY WILLISTON, LLC
Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.
Overlapping units
5 other units share a surveyed well with this one; overlapping units are not additive.
- T152N R104W sections 22, 27 1,280-acre Bakken spacing unit
- T152N R104W sections 27, 28, 29, 30 2,240-acre Bakken spacing unit
- T152N R104W sections 19, 20, 21, 22 2,240-acre Bakken spacing unit
- T152N R104W sections 19, 30 640-acre Bakken spacing unit
- T152N R104W sections 20, 29 1,280-acre Bakken spacing unit