Spacing unit · Mountrail County
640-acre Bakken spacing unit
T150N R91W sections 7, 8
Unit facts
- Formation
- Bakken
- Acres
- 640
- Type
- Spacing unit
- Land described
- T150N R91W sections 7, 8
- Pool
- Van Hook-Bakken
- Zone
- Zone I
- County
- Mountrail County
- Surveyed wells inside
- 5
- Most wells operated by
- Devon Energy
- Unit id
dsu-e5d697d1bcdde5e46e54- Wells allowed by the latest linked order
- 1
- Wells assigned to this unit
- 2
- Pending permits inside
- 0
- Balance under the allowance
- -4
- First linked order
- Aug 21, 2014
- Review note
- wells_predate_linked_orders
- Laterals that still fit (Nov 2026 method)
- 0
- Neighbourhood target density
- 8.37 two-mile laterals per 1,280 acres
- Density drilled so far
- 6.25 per 1,280 acres
Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. 1 more would fit the density but not the spacing rule. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.
Map
DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.
Wells inside the unit
| Well | Operator | Status | Lateral inside |
|---|---|---|---|
| EDWARD FLIES AWAY 7-8-9HZ | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,019 ft66% |
| EDWARD FLIES AWAY 7-8-9HC | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,889 ft100% |
| OWL COMES OUT 8-9HC | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 5,161 ft51% |
| EDWARD FLIES AWAY 7-8-9HB | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 4,508 ft100% |
| EDWARD FLIES AWAY 7-8-9HY | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 2,872 ft19% |
Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.
Order history
- Order 24838Case 22504Designated the spacing unitQEP ENERGY CO.
- Order 25001Case 22666Established the spacing unit, 1 well allowedWPX ENERGY WILLISTON, LLC
- Order 25001Case 22666Established the spacing unitWPX ENERGY WILLISTON, LLC
- Order 25509Case 23178Pooled all interests in the unitWPX ENERGY WILLISTON, LLC
- Order 35220Case 32449Designated the spacing unitSPOTTED HAWK DEVELOPMENT, LLC
Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.
Overlapping units
3 other units share a surveyed well with this one; overlapping units are not additive.
- T150N R91W sections 4, 5, 6, 7, 8, 9 3,840-acre Bakken spacing unit
- T150N R91W sections 7, 8, 9, 16, 17, 18 3,840-acre Bakken spacing unit
- T150N R91W sections 7, 8, 9 1,920-acre Bakken spacing unit