BBakken SubsurfaceNorth Dakota well index

Spacing unit · Dunn County

1,280-acre Bakken spacing unit

T147N R96W sections 22, 27

Spacing unit16 wells allowed · order 30745Oakdale-Bakken

Unit facts

Formation
Bakken
Acres
1,280
Type
Spacing unit
Land described
T147N R96W sections 22, 27
Pool
Oakdale-Bakken
Zone
Zone III
County
Dunn County
Surveyed wells inside
18
Most wells operated by
Continental Resources
Unit id
dsu-e9eb7ce715bfb7ad18c5
Wells allowed by the latest linked order
16
Wells assigned to this unit
18
Pending permits inside
0
Balance under the allowance
-2
First linked order
Jul 20, 2009
Review note
over_allowance
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
10.86 two-mile laterals per 1,280 acres
Density drilled so far
16.21 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

HAWKINSON 15-22HHAWKINSON 13-22HHAWKINSON 1-22HHAWKINSON 10-22H1HAWKINSON 5-22HHAWKINSON 2-27HCARUS 12-28HSL1HAWKINSON 16-22HSL1HAWKINSON 3-27HHAWKINSON 7-22H2HAWKINSON 11-22H2HAWKINSON 9-22H3HAWKINSON 8-22HHAWKINSON 6-22H3HAWKINSON 12-22H3HAWKINSON 4-22H2HAWKINSON 14-22H2INTERSTELLAR SWD1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
HAWKINSON 15-22HCONTINENTAL RESOURCES, INC.Active (A)10,958 ft100%
HAWKINSON 13-22HCONTINENTAL RESOURCES, INC.Active (A)10,886 ft100%
HAWKINSON 1-22HCONTINENTAL RESOURCES, INC.Inactive (IA)10,643 ft100%
HAWKINSON 10-22H1CONTINENTAL RESOURCES, INC.Inactive (IA)10,545 ft100%
HAWKINSON 5-22HCONTINENTAL RESOURCES, INC.Active (A)10,345 ft100%
HAWKINSON 2-27HCONTINENTAL RESOURCES, INC.Active (A)10,318 ft100%
CARUS 12-28HSL1CONTINENTAL RESOURCES, INC.Active (A)10,291 ft100%
HAWKINSON 16-22HSL1CONTINENTAL RESOURCES, INC.Active (A)10,118 ft100%
HAWKINSON 3-27HCONTINENTAL RESOURCES, INC.Inactive (IA)10,083 ft100%
HAWKINSON 7-22H2CONTINENTAL RESOURCES, INC.Active (A)9,765 ft100%
HAWKINSON 11-22H2CONTINENTAL RESOURCES, INC.Active (A)9,671 ft100%
HAWKINSON 9-22H3CONTINENTAL RESOURCES, INC.Temporarily abandoned (TA)9,613 ft100%
HAWKINSON 8-22HCONTINENTAL RESOURCES, INC.Active (A)9,596 ft100%
HAWKINSON 6-22H3CONTINENTAL RESOURCES, INC.Inactive (IA)9,526 ft100%
HAWKINSON 12-22H3CONTINENTAL RESOURCES, INC.Active (A)9,508 ft100%
HAWKINSON 4-22H2CONTINENTAL RESOURCES, INC.Active (A)9,494 ft100%
HAWKINSON 14-22H2CONTINENTAL RESOURCES, INC.Abandoned (AB)9,321 ft100%
INTERSTELLAR SWDCONTINENTAL RESOURCES, INC.Active (A)1,509 ft100%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 13262Case 11185Established the spacing unitCONTINENTAL RESOURCES, INC.
  2. Order 13956Case 11790Designated the spacing unit, 2 wells allowedCONTINENTAL RESOURCES, INC.
  3. Order 14048Case 11867Pooled all interests in the unitCONTINENTAL RESOURCES, INC.
  4. Order 14392Case 12140Designated the spacing unit
  5. Order 15126Case 12859Established the spacing unit, 1 well allowedCONTINENTAL RESOURCES, INC.
  6. Order 20972Case 18670Established the spacing unit, 16 wells allowedCONTINENTAL RESOURCES, INC.
  7. Order 29267Case 26827Affirmed the spacing unit

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

3 other units share a surveyed well with this one; overlapping units are not additive.