Spacing unit · Burke County
1,280-acre Bakken spacing unit
T159N R91W sections 2, 11
Unit facts
- Formation
- Bakken
- Acres
- 1,280
- Type
- Spacing unit
- Land described
- T159N R91W sections 2, 11
- Pool
- Thompson Lake-Bakken
- Zone
- Zone V
- County
- Burke County
- Surveyed wells inside
- 1
- Most wells operated by
- EOG Resources
- Unit id
dsu-ea92e034343209b4814c- Wells allowed by the latest linked order
- 1
- Wells assigned to this unit
- 1
- Pending permits inside
- 0
- Balance under the allowance
- 0
- First linked order
- Oct 20, 2010
- Laterals that still fit (Nov 2026 method)
- 2 (1.91 two-mile equivalents)
- Neighbourhood target density
- 2.89 two-mile laterals per 1,280 acres
- Density drilled so far
- 0.9 per 1,280 acres
Room to drill: 2 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.
Map
DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.
Wells inside the unit
| Well | Operator | Status | Lateral inside |
|---|---|---|---|
| VANVILLE 15-1102H | EOG RESOURCES, INC. | Active (A) | 9,544 ft100% |
Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.
Order history
- Order 14792Case 12535Established the spacing unit, 3 wells allowedEOG RESOURCES, INC.
- Order 16430Case 14155Pooled all interests in the unitEOG RESOURCES, INC.
- Order 34747Case 31994Established the spacing unit, 1 well allowedHUNT OIL CO.
- Order 34747Case 31994Designated the spacing unitHUNT OIL CO.
- Order 34862Case 32173Designated the spacing unitHUNT OIL CO.
Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.
Overlapping units
One other unit shares a surveyed well with this one; overlapping units are not additive.
- T159N R91W sections 2, 11, 14 1,920-acre Bakken spacing unit