BBakken SubsurfaceNorth Dakota well index

Spacing unit · Dunn County

640-acre Bakken spacing unit

T148N R96W section 4

Spacing unit3 wells allowed · order 35872Lost Bridge-Bakken

Unit facts

Formation
Bakken
Acres
640
Type
Spacing unit
Land described
T148N R96W section 4
Pool
Lost Bridge-Bakken
Zone
Zone II
County
Dunn County
Surveyed wells inside
9
Most wells operated by
Devon Energy
Unit id
dsu-f1ce6ed6b558bf6409b1
Wells allowed by the latest linked order
3
Wells assigned to this unit
1
Pending permits inside
0
Balance under the allowance
-6
First linked order
Oct 26, 2007
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
10.73 two-mile laterals per 1,280 acres
Density drilled so far
8.58 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. 2 more would fit the density but not the spacing rule. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

LOST BRIDGE FEDERAL 148-96-9-4-4HLWLOST BRIDGE FEDERAL 148-96-9-4-13HLOST BRIDGE FEDERAL 148-96-9-4-3HLOST BRIDGE FEDERAL 148-96-9-4-12HLOST BRIDGE FEDERAL 148-96-9-4-2HLOST BRIDGE FEDERAL 148-96-9-4-11HLOST BRIDGE FEDERAL 148-96-9-4-1HLOST BRIDGE FEDERAL 148-96-9-4-10HJORGENSON 1-4H1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
LOST BRIDGE FEDERAL 148-96-9-4-4HLWDEVON ENERGY WILLISTON, L.L.C.Active (A)4,586 ft48%
LOST BRIDGE FEDERAL 148-96-9-4-13HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,581 ft48%
LOST BRIDGE FEDERAL 148-96-9-4-3HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,579 ft47%
LOST BRIDGE FEDERAL 148-96-9-4-12HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,571 ft47%
LOST BRIDGE FEDERAL 148-96-9-4-2HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,564 ft46%
LOST BRIDGE FEDERAL 148-96-9-4-11HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,554 ft47%
LOST BRIDGE FEDERAL 148-96-9-4-1HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,554 ft48%
LOST BRIDGE FEDERAL 148-96-9-4-10HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,544 ft47%
JORGENSON 1-4HDEEP CREEK ADVENTURES, CO.Plugged and abandoned (PA)4,452 ft100%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 11392Case 9682Created the spacing unitNANCE PETROLEUM CORP.
  2. Order 13710Case 11436Pooled all interests in the unitNEWFIELD PRODUCTION CO.
  3. Order 14598Case 12346Listed the unit in a pool zone table, 2 wells allowedXTO ENERGY INC.
  4. Order 23097Case 20791Established the spacing unit, 3 wells allowedNEWFIELD PRODUCTION CO.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

4 other units share a surveyed well with this one; overlapping units are not additive.