Spacing unit · McKenzie County
2,240-acre Bakken spacing unit
T152N R104W sections 31, 32, 33, 34
Unit facts
- Formation
- Bakken
- Acres
- 2,240
- Type
- Spacing unit
- Land described
- T152N R104W sections 31, 32, 33, 34
- Pool
- Briar Creek-Bakken
- Zone
- Zone XI
- County
- McKenzie County
- Surveyed wells inside
- 10
- Most wells operated by
- Devon Energy
- Unit id
dsu-fadb9849cdd0fa5852bd- Wells allowed by the latest linked order
- 5
- Wells assigned to this unit
- 5
- Pending permits inside
- 0
- Balance under the allowance
- -4
- First linked order
- Feb 1, 2022
- Laterals that still fit (Nov 2026 method)
- 0
- Neighbourhood target density
- 4.33 two-mile laterals per 1,280 acres
- Density drilled so far
- 5.96 per 1,280 acres
Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.
Map
DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.
Wells inside the unit
| Well | Operator | Status | Lateral inside |
|---|---|---|---|
| SPONHEIM 31-34F 1H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 17,191 ft100% |
| SPONHEIM 31-34F 2H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 17,037 ft100% |
| SPONHEIM 31-34F 4H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 16,779 ft100% |
| SPONHEIM 31-34F 5H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 16,167 ft100% |
| SPONHEIM 31-34F 3H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 16,139 ft100% |
| HERMAN JOHNSON 32-5 #1-H | DEVON ENERGY WILLISTON, L.L.C. | Inactive (IA) | 10,351 ft54% |
| PVT. FRAZIER 1-34H | Zavanna Energy Operating, LLC | Plugged and abandoned (PA) | 7,602 ft100% |
| GYDA 31-6 1H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 5,183 ft51% |
| LUND 3-34 1H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 4,973 ft52% |
| SEDLACEK TRUST 33-4 1-H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 4,317 ft48% |
Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.
Order history
- Order 31677Case 29115Established the spacing unit, 4 wells allowedGRAYSON MILL OPERATING, LLC
- Order 31693Case 29131Pooled all interests in the unitGRAYSON MILL OPERATING, LLC
- Order 33080Case 30467Established the spacing unit, 5 wells allowedGRAYSON MILL OPERATING, LLC
Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.
Overlapping units
6 other units share a surveyed well with this one; overlapping units are not additive.
- T152N R104W section 33 1,280-acre Bakken spacing unit
- T152N R104W section 32 1,280-acre Bakken spacing unit
- T152N R104W section 34 1,280-acre Bakken spacing unit
- T152N R104W sections 34, 35 2,560-acre Bakken spacing unit
- T151N R104W sections 3, 4, 5, 6 2,240-acre Bakken spacing unit
- T152N R104W section 31 640-acre Bakken spacing unit