BBakken SubsurfaceNorth Dakota well index

Spacing unit · McKenzie County

2,560-acre Bakken spacing unit

T150N R101W sections 18, 19, 30, 31

Spacing unit3 wells allowed · order 34539Pronghorn-Bakken

Unit facts

Formation
Bakken
Acres
2,560
Type
Spacing unit
Land described
T150N R101W sections 18, 19, 30, 31
Pool
Pronghorn-Bakken
Zone
Zone XI
County
McKenzie County
Surveyed wells inside
10
Most wells operated by
Chord / Enerplus / Oasis / Whiting
Unit id
dsu-fdda66c9c94dd60787ff
Wells allowed by the latest linked order
3
Wells assigned to this unit
3
Pending permits inside
0
Balance under the allowance
-5
First linked order
Nov 2, 2015
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
5.31 two-mile laterals per 1,280 acres
Density drilled so far
5.62 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

TOONIE 5001 11-18 4BTOONIE 5001 11-18 3BTOONIE 5001 11-18 5BTOONIE 5001 11-18 2BXHELLING 19-18HHELLING 30-31HJacobson 150-101-17-20-13HFRITZ 150-101-32-29-13HSHEFFIELD 1-30HMUSIAL 1-18H1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
TOONIE 5001 11-18 4BWHITING OIL AND GAS CORPORATIONActive (A)20,900 ft100%
TOONIE 5001 11-18 3BWHITING OIL AND GAS CORPORATIONActive (A)20,835 ft100%
TOONIE 5001 11-18 5BWHITING OIL AND GAS CORPORATIONActive (A)20,765 ft100%
TOONIE 5001 11-18 2BXWHITING OIL AND GAS CORPORATIONActive (A)13,889 ft59%
HELLING 19-18HWHITING OIL AND GAS CORPORATIONActive (A)10,773 ft100%
HELLING 30-31HWHITING OIL AND GAS CORPORATIONActive (A)10,174 ft100%
Jacobson 150-101-17-20-13HKRAKEN OPERATING, LLCActive (A)9,835 ft100%
FRITZ 150-101-32-29-13HKRAKEN OPERATING, LLCActive (A)9,755 ft95%
SHEFFIELD 1-30HBURNETT ENERGY INC.Active (A)4,358 ft100%
MUSIAL 1-18HBURNETT ENERGY INC.Active (A)3,253 ft100%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 24306Case 21973Listed the unit in a pool zone table, 2 wells allowedWHITING OIL AND GAS CORP.
  2. Order 34229Case 31507Established the spacing unit, 3 wells allowedWHITING OIL AND GAS CORP.
  3. Order 34229Case 31507Listed the unit in a pool zone table, 2 wells allowedWHITING OIL AND GAS CORP.
  4. Order 34237Case 31515Pooled all interests in the unitWHITING OIL AND GAS CORP.
  5. Order 34539Case 31802Designated the spacing unit, 3 wells allowedKRAKEN OPERATING, LLC
  6. Order 34539Case 31802Listed the unit in a pool zone table, 2 wells allowedKRAKEN OPERATING, LLC

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

8 other units share a surveyed well with this one; overlapping units are not additive.