BBakken SubsurfaceNorth Dakota well index

Spacing unit · Dunn County

1,280-acre Bakken spacing unit

T149N R92W section 36

Spacing unit12 wells allowed · order 35852Heart Butte-Bakken

Unit facts

Formation
Bakken
Acres
1,280
Type
Spacing unit
Land described
T149N R92W section 36
Pool
Heart Butte-Bakken
Zone
Zone XXXV
County
Dunn County
Surveyed wells inside
9
Most wells operated by
XTO Energy
DMR case / order on the footprint
11447 /
Unit id
dsu-fe0b1a4f730c3b06f307
Wells allowed by the latest linked order
12
Wells assigned to this unit
0
Pending permits inside
0
Balance under the allowance
+3
First linked order
Sep 28, 2009
Laterals that still fit (Nov 2026 method)
1 (0.92 two-mile equivalents)
Neighbourhood target density
9.39 two-mile laterals per 1,280 acres
Density drilled so far
7.96 per 1,280 acres

Room to drill: 1 lateral still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

FBIR YELLOWWOLF 21X-10FBIR YELLOWWOLF 31X-10CFBIR YELLOWWOLF 21X-10EFBIR YELLOWWOLF 31X-10DFBIR YELLOWWOLF 21X-10AFBIR YELLOWWOLF 21X-10FFBIR YELLOWWOLF 31X-10GFBIR WALKER 31X-36DXAFBIR WALKER 31X-36HXE1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
FBIR YELLOWWOLF 21X-10XTO ENERGY INCActive (A)11,259 ft100%
FBIR YELLOWWOLF 31X-10CXTO ENERGY INCActive (A)9,956 ft100%
FBIR YELLOWWOLF 21X-10EXTO ENERGY INCActive (A)9,878 ft100%
FBIR YELLOWWOLF 31X-10DXTO ENERGY INCActive (A)9,830 ft100%
FBIR YELLOWWOLF 21X-10AXTO ENERGY INCActive (A)9,820 ft100%
FBIR YELLOWWOLF 21X-10FXTO ENERGY INCActive (A)9,808 ft100%
FBIR YELLOWWOLF 31X-10GXTO ENERGY INCActive (A)9,787 ft100%
FBIR WALKER 31X-36DXAXTO ENERGY INCActive (A)9,582 ft100%
FBIR WALKER 31X-36HXEXTO ENERGY INCActive (A)1,005 ft11%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 13568Case 11447Established the spacing unitXTO ENERGY INC.
  2. Order 13817Case 11669Designated the spacing unitQUESTAR EXPL. AND PROD. CO.
  3. Order 14375Case 12125Designated the spacing unitKODIAK OIL & GAS (USA) INC.
  4. Order 14494Case 12243Designated the spacing unit, 2 wells allowedPEAK NORTH DAKOTA, LLC
  5. Order 16640Case 14363Designated the spacing unit, 6 wells allowedENERPLUS RESOURCES (U.S.A.) INC.
  6. Order 17367Case 15119Established the spacing unit, 6 wells allowedXTO ENERGY INC.
  7. Order 17357Case 15106Pooled all interests in the unitXTO ENERGY INC.
  8. Order 17625Case 15379Designated the spacing unit, 4 wells allowedQEP ENERGY CO.
  9. Order 18007Case 15752Designated the spacing unit, 6 wells allowedDAKOTA-3 E&P CO., LLC
  10. Order 18717Case 16451Designated the spacing unit, 6 wells allowedENERPLUS RESOURCES (U.S.A.) INC.
  11. Order 18222Case 15960Designated the spacing unit, 8 wells allowedDAKOTA-3 E&P CO., LLC
  12. Order 20494Case 18225Designated the spacing unit, 8 wells allowedKODIAK OIL & GAS (USA) INC.
  13. Order 21676Case 19373Established the spacing unit, 8 wells allowedXTO ENERGY INC.
  14. Order 26814Case 24448Designated the spacing unit, 8 wells allowedWHITING OIL AND GAS CORP.
  15. Order 26745Case 24378Listed the unit in a pool zone table, 12 wells allowedQEP ENERGY CO.
  16. Order 26872Case 24506Designated the spacing unit, 12 wells allowedQEP ENERGY CO.
  17. Order 27023Case 24659Established the spacing unit, 12 wells allowedXTO ENERGY INC.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

4 other units share a surveyed well with this one; overlapping units are not additive.