BBakken SubsurfaceNorth Dakota well index

Spacing unit · McKenzie County

2,560-acre Bakken spacing unit

T150N R98W sections 13, 24

Spacing unit2 wells allowed · order 34449Siverston-Bakken

Unit facts

Formation
Bakken
Acres
2,560
Type
Spacing unit
Land described
T150N R98W sections 13, 24
Pool
Siverston-Bakken
Zone
Zone XIV
County
McKenzie County
Surveyed wells inside
21
Most wells operated by
Devon Energy
Unit id
dsu-156cc3176b8863e59408
Wells allowed by the latest linked order
2
Wells assigned to this unit
0
Pending permits inside
0
Balance under the allowance
-19
First linked order
Feb 12, 2014
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
9.52 two-mile laterals per 1,280 acres
Density drilled so far
9.72 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

COSTANZA 24-13 1TFHKRAMER 150-97-18-19-5HRCOSTANZA 24-13 7TFHCOSTANZA 24-13 2HCOSTANZA 24-13 3TFHCOSTANZA 24-13 4HCOSTANZA 24-13 6HCOSTANZA 24-13 8HKRAMER 150-97-18-19-4HLUNDIN 11-13SEHKRAMER 150-97-18-19-3HCOSTANZA 24-13 5TFHKRAMER 150-97-18-19-14HKRAMER 150-97-18-19-1HLWKRAMER 150-97-18-19-13HKRAMER 150-97-18-19-15HKRAMER 150-97-18-19-2HKRAMER 150-97-18-19-12HLUND 26-18SHKRAMER 150-97-18-19-11HLWLUND 21X-17AXD1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
COSTANZA 24-13 1TFHDEVON ENERGY WILLISTON, L.L.C.Active (A)10,663 ft100%
KRAMER 150-97-18-19-5HRDEVON ENERGY WILLISTON, L.L.C.Active (A)10,251 ft100%
COSTANZA 24-13 7TFHDEVON ENERGY WILLISTON, L.L.C.Active (A)10,229 ft100%
COSTANZA 24-13 2HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,225 ft100%
COSTANZA 24-13 3TFHDEVON ENERGY WILLISTON, L.L.C.Active (A)10,219 ft100%
COSTANZA 24-13 4HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,215 ft100%
COSTANZA 24-13 6HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,200 ft100%
COSTANZA 24-13 8HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,195 ft100%
KRAMER 150-97-18-19-4HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,170 ft100%
LUNDIN 11-13SEHDEVON ENERGY WILLISTON, L.L.C.Abandoned (AB)10,153 ft100%
KRAMER 150-97-18-19-3HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,126 ft100%
COSTANZA 24-13 5TFHDEVON ENERGY WILLISTON, L.L.C.Active (A)10,125 ft100%
KRAMER 150-97-18-19-14HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,109 ft100%
KRAMER 150-97-18-19-1HLWDEVON ENERGY WILLISTON, L.L.C.Active (A)10,100 ft100%
KRAMER 150-97-18-19-13HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,074 ft100%
KRAMER 150-97-18-19-15HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,052 ft100%
KRAMER 150-97-18-19-2HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,047 ft100%
KRAMER 150-97-18-19-12HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,004 ft100%
LUND 26-18SHDEVON ENERGY WILLISTON, L.L.C.Active (A)8,959 ft100%
KRAMER 150-97-18-19-11HLWDEVON ENERGY WILLISTON, L.L.C.Active (A)7,649 ft100%
LUND 21X-17AXDXTO ENERGY INCActive (A)6,111 ft61%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 23464Case 21160Established the spacing unit, 1 well allowedXTO ENERGY INC.
  2. Order 23464Case 21160Designated the spacing unitXTO ENERGY INC.
  3. Order 29876Case 27432Designated the spacing unitNEWFIELD PRODUCTION CO.
  4. Order 30634Case 28178Pooled all interests in the unitNEWFIELD PRODUCTION CO.
  5. Order 30062Case 27618Designated the spacing unit, 2 wells allowedXTO ENERGY INC.
  6. Order 30596Case 28144Established the spacing unit, 2 wells allowedNEWFIELD PRODUCTION CO.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

7 other units share a surveyed well with this one; overlapping units are not additive.