BBakken SubsurfaceNorth Dakota well index

Spacing unit · McKenzie County

2,560-acre Bakken spacing unit

T150N R97W sections 16, 17, 20, 21

Spacing unit2 wells allowed · order 30851Siverston-Bakken

Unit facts

Formation
Bakken
Acres
2,560
Type
Spacing unit
Land described
T150N R97W sections 16, 17, 20, 21
Pool
Siverston-Bakken
Zone
Zone XIII
County
McKenzie County
Surveyed wells inside
24
Most wells operated by
Devon Energy
Unit id
dsu-4dbd49bca15921bbab98
Wells allowed by the latest linked order
2
Wells assigned to this unit
1
Pending permits inside
0
Balance under the allowance
-22
First linked order
Feb 12, 2014
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
9.6 two-mile laterals per 1,280 acres
Density drilled so far
10.57 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

NEWMAN 150-97-21-16-13HNEWMAN 150-97-21-16-5HNEWMAN 150-97-21-16-7HLUND 41X-17GNEWMAN 150-97-21-16-14HNEWMAN 150-97-21-16-6HRNEWMAN 150-97-21-16-2HNEWMAN 150-97-21-16-6HNEWMAN 150-97-21-16-1HLUND 41X-17HXENEWMAN 150-97-21-16-12HLUND 21X-17BNEWMAN 150-97-21-16-15HLUND 21X-17ENEWMAN 150-97-21-16-8HLWLUND 41X-17DLUND 21X-17FLUND 21X-17ALUND 41X-17H2LUND 41X-17CSTENEHJEM 44-21HTITAN E-GIERKE 20-1-HLUND 44-8SHLUND 21X-17AXD1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
NEWMAN 150-97-21-16-13HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,910 ft100%
NEWMAN 150-97-21-16-5HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,135 ft100%
NEWMAN 150-97-21-16-7HDEVON ENERGY WILLISTON, L.L.C.Plugged and abandoned (PA)10,100 ft100%
LUND 41X-17GXTO ENERGY INCActive (A)10,096 ft100%
NEWMAN 150-97-21-16-14HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,088 ft100%
NEWMAN 150-97-21-16-6HRDEVON ENERGY WILLISTON, L.L.C.Active (A)10,076 ft100%
NEWMAN 150-97-21-16-2HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,066 ft100%
NEWMAN 150-97-21-16-6HDEVON ENERGY WILLISTON, L.L.C.Plugged and abandoned (PA)10,052 ft100%
NEWMAN 150-97-21-16-1HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,050 ft100%
LUND 41X-17HXEXTO ENERGY INCActive (A)10,025 ft100%
NEWMAN 150-97-21-16-12HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,011 ft100%
LUND 21X-17BXTO ENERGY INCActive (A)9,862 ft100%
NEWMAN 150-97-21-16-15HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,814 ft100%
LUND 21X-17EXTO ENERGY INCActive (A)9,780 ft100%
NEWMAN 150-97-21-16-8HLWDEVON ENERGY WILLISTON, L.L.C.Active (A)9,725 ft96%
LUND 41X-17DXTO ENERGY INCActive (A)9,664 ft100%
LUND 21X-17FXTO ENERGY INCActive (A)9,578 ft100%
LUND 21X-17AXTO ENERGY INCActive (A)9,527 ft100%
LUND 41X-17H2XTO ENERGY INCActive (A)9,527 ft100%
LUND 41X-17CXTO ENERGY INCActive (A)9,452 ft100%
STENEHJEM 44-21HDEVON ENERGY WILLISTON, L.L.C.Inactive (IA)9,307 ft100%
TITAN E-GIERKE 20-1-HXTO ENERGY INCPlugged and abandoned (PA)5,397 ft100%
LUND 44-8SHXTO ENERGY INCActive (A)4,762 ft100%
LUND 21X-17AXDXTO ENERGY INCActive (A)3,933 ft39%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 23464Case 21160Established the spacing unit, 1 well allowedXTO ENERGY INC.
  2. Order 23464Case 21160Designated the spacing unitXTO ENERGY INC.
  3. Order 27329Case 24938Pooled all interests in the unitXTO ENERGY INC.
  4. Order 30851Case 28393Designated the spacing unit, 2 wells allowedOVINTIV PRODUCTION INC.
  5. Order 34449Case 31713Designated the spacing unitDEVON ENERGY WILLISTON, LLC

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

8 other units share a surveyed well with this one; overlapping units are not additive.