Spacing unit · McKenzie County
2,560-acre Bakken spacing unit
T152N R96W sections 26, 27, 34, 35
Unit facts
- Formation
- Bakken
- Acres
- 2,560
- Type
- Spacing unit
- Land described
- T152N R96W sections 26, 27, 34, 35
- Pool
- Clear Creek-Bakken
- Zone
- Zone X
- County
- McKenzie County
- Surveyed wells inside
- 26
- Most wells operated by
- Petro-Hunt
- Unit id
dsu-189def22d86b76df987e- Wells allowed by the latest linked order
- 2
- Wells assigned to this unit
- 1
- Pending permits inside
- 0
- Balance under the allowance
- -23
- First linked order
- Sep 4, 2013
- Laterals that still fit (Nov 2026 method)
- 0
- Neighbourhood target density
- 10.22 two-mile laterals per 1,280 acres
- Density drilled so far
- 8.31 per 1,280 acres
Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.
Map
DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.
Wells inside the unit
| Well | Operator | Status | Lateral inside |
|---|---|---|---|
| Wollan Creek 152-96-34D-27-3H | PETRO-HUNT, L.L.C. | Active (A) | 10,494 ft100% |
| Wollan Creek 152-96-34C-27-1H | PETRO-HUNT, L.L.C. | Active (A) | 10,472 ft100% |
| Wollan Creek 152-96-34D-27-2H | PETRO-HUNT, L.L.C. | Active (A) | 10,457 ft100% |
| JONSRUD 152-96-34C-27-2HS | PETRO-HUNT, L.L.C. | Active (A) | 10,094 ft100% |
| ANDERSON 152-96-35C-26-2H | PETRO-HUNT, L.L.C. | Active (A) | 9,838 ft100% |
| ANDERSON 152-96-35C-26-3H | PETRO-HUNT, L.L.C. | Active (A) | 9,641 ft100% |
| ANDERSON 152-96-35D-26-4H | PETRO-HUNT, L.L.C. | Active (A) | 9,629 ft100% |
| ANDERSON 152-96-35D-26-6H | PETRO-HUNT, L.L.C. | Active (A) | 9,417 ft100% |
| ANDERSON 152-96-35D-26-5H | PETRO-HUNT, L.L.C. | Active (A) | 9,363 ft100% |
| WOLLAN 152-96-27A-35-1HS | PETRO-HUNT, L.L.C. | Active (A) | 9,261 ft100% |
| ANDERSON 152-96-35C-26-1H | PETRO-HUNT, L.L.C. | Active (A) | 9,096 ft100% |
| ANDERSON 152-96-35D-26-1HS | PETRO-HUNT, L.L.C. | Active (A) | 7,189 ft72% |
| CLEAR CREEK-MADISON UNIT 26B-4-1H | PETRO-HUNT, L.L.C. | Abandoned (AB) | 5,084 ft100% |
| WOLLAN 152-96-27D-3H | PETRO-HUNT, L.L.C. | Active (A) | 5,058 ft100% |
| CLEAR CREEK 152-96-34A-3H | PETRO-HUNT, L.L.C. | Active (A) | 4,900 ft100% |
| CLEAR CREEK 152-96-34A-4H | PETRO-HUNT, L.L.C. | Active (A) | 4,885 ft100% |
| WOLLAN 152-96-27D-4H | PETRO-HUNT, L.L.C. | Active (A) | 4,882 ft100% |
| CLEAR CREEK 152-96-34D-2H | PETRO-HUNT, L.L.C. | Active (A) | 4,865 ft100% |
| CLEAR CREEK 152-96-34C-1H | PETRO-HUNT, L.L.C. | Active (A) | 4,853 ft100% |
| WOLLAN 152-96-27C-6H | PETRO-HUNT, L.L.C. | Inactive (IA) | 4,628 ft100% |
| ANDERSON 152-96-26B-25-2HS | PETRO-HUNT, L.L.C. | Active (A) | 4,591 ft44% |
| CLEAR CREEK 152-96-34B-6H | PETRO-HUNT, L.L.C. | Active (A) | 4,419 ft100% |
| CLEAR CREEK 152-96-34B-5H | PETRO-HUNT, L.L.C. | Active (A) | 4,366 ft100% |
| WOLLAN 152-96-27A-5H | PETRO-HUNT, L.L.C. | Active (A) | 4,275 ft100% |
| WOLLAN 27A-2-2H | PETRO-HUNT, L.L.C. | Active (A) | 4,235 ft100% |
| WOLLAN 27B-2-2H | PETRO-HUNT, L.L.C. | Inactive (IA) | 3,936 ft100% |
Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.
Order history
- Order 22330Case 20025Established the spacing unit, 2 wells allowedPETRO- HUNT, LLC
- Order 24962Case 22627Pooled all interests in the unitPETRO- HUNT, L.L.C.
Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.
Overlapping units
17 other units share a surveyed well with this one; overlapping units are not additive.
- T152N R96W sections 25, 26, 35, 36 2,560-acre Bakken spacing unit
- T152N R96W sections 13, 24 2,560-acre Bakken spacing unit
- T152N R96W section 34 640-acre Bakken spacing unit
- T152N R96W sections 13, 14, 23, 24 2,560-acre Bakken spacing unit
- T152N R96W sections 25, 36 1,280-acre Bakken spacing unit
- T152N R96W sections 14, 23 1,280-acre Bakken spacing unit
- T152N R96W sections 26, 35 1,280-acre Bakken spacing unit
- T152N R96W section 27 320-acre Bakken drilling unit
- T152N R96W sections 23, 24, 25, 26 2,560-acre Bakken spacing unit
- T152N R96W sections 25, 36 2,560-acre Bakken spacing unit
- T152N R96W sections 14, 15, 22, 23 2,560-acre Bakken spacing unit
- T152N R96W sections 27, 28, 33, 34 2,560-acre Bakken spacing unit
- T152N R96W sections 13, 24 1,280-acre Bakken spacing unit
- T152N R96W section 27 320-acre Bakken drilling unit
- T152N R96W section 27 640-acre Bakken spacing unit
- T152N R96W sections 27, 34 1,280-acre Bakken spacing unit
- T152N R96W sections 25, 36 2,560-acre Bakken spacing unit