BBakken SubsurfaceNorth Dakota well index

Spacing unit · McKenzie County

2,560-acre Bakken spacing unit

T152N R96W sections 27, 28, 33, 34

Spacing unit2 wells allowed · order 32217Clear Creek-Bakken

Unit facts

Formation
Bakken
Acres
2,560
Type
Spacing unit
Land described
T152N R96W sections 27, 28, 33, 34
Pool
Clear Creek-Bakken
Zone
Zone X
County
McKenzie County
Surveyed wells inside
24
Most wells operated by
Petro-Hunt
Unit id
dsu-c061269e6cdec286a147
Wells allowed by the latest linked order
2
Wells assigned to this unit
1
Pending permits inside
0
Balance under the allowance
-22
First linked order
Sep 4, 2013
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
10.2 two-mile laterals per 1,280 acres
Density drilled so far
8.45 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

WISNESS 152-96-28A-33-2HJONSRUD 152-96-33D-28-1HSWollan Creek 152-96-34D-27-3HWollan Creek 152-96-34C-27-1HWollan Creek 152-96-34D-27-2HWISNESS 152-96-33C-28-4HWISNESS 152-96-28A-33-6HJONSRUD 152-96-34C-27-2HSWISNESS 152-96-28A-33-1HWISNESS 152-96-33C-28-5HWISNESS 152-96-28A-33-3HROLFSRUD STATE 152-96-29-32-13HLWWOLLAN 152-96-27D-3HCLEAR CREEK 152-96-34A-3HCLEAR CREEK 152-96-34A-4HWOLLAN 152-96-27D-4HCLEAR CREEK 152-96-34D-2HCLEAR CREEK 152-96-34C-1HWOLLAN 152-96-27C-6HCLEAR CREEK 152-96-34B-6HCLEAR CREEK 152-96-34B-5HWOLLAN 152-96-27A-5HWOLLAN 27A-2-2HWOLLAN 27B-2-2H1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
WISNESS 152-96-28A-33-2HPETRO-HUNT, L.L.C.Active (A)14,861 ft100%
JONSRUD 152-96-33D-28-1HSPETRO-HUNT, L.L.C.Active (A)11,903 ft100%
Wollan Creek 152-96-34D-27-3HPETRO-HUNT, L.L.C.Active (A)10,494 ft100%
Wollan Creek 152-96-34C-27-1HPETRO-HUNT, L.L.C.Active (A)10,472 ft100%
Wollan Creek 152-96-34D-27-2HPETRO-HUNT, L.L.C.Active (A)10,457 ft100%
WISNESS 152-96-33C-28-4HPETRO-HUNT, L.L.C.Active (A)10,212 ft100%
WISNESS 152-96-28A-33-6HPETRO-HUNT, L.L.C.Active (A)10,107 ft100%
JONSRUD 152-96-34C-27-2HSPETRO-HUNT, L.L.C.Active (A)10,094 ft100%
WISNESS 152-96-28A-33-1HPETRO-HUNT, L.L.C.Active (A)9,962 ft100%
WISNESS 152-96-33C-28-5HPETRO-HUNT, L.L.C.Active (A)9,683 ft100%
WISNESS 152-96-28A-33-3HPETRO-HUNT, L.L.C.Active (A)9,535 ft100%
ROLFSRUD STATE 152-96-29-32-13HLWDEVON ENERGY WILLISTON, L.L.C.Active (A)5,122 ft50%
WOLLAN 152-96-27D-3HPETRO-HUNT, L.L.C.Active (A)5,058 ft100%
CLEAR CREEK 152-96-34A-3HPETRO-HUNT, L.L.C.Active (A)4,900 ft100%
CLEAR CREEK 152-96-34A-4HPETRO-HUNT, L.L.C.Active (A)4,885 ft100%
WOLLAN 152-96-27D-4HPETRO-HUNT, L.L.C.Active (A)4,882 ft100%
CLEAR CREEK 152-96-34D-2HPETRO-HUNT, L.L.C.Active (A)4,865 ft100%
CLEAR CREEK 152-96-34C-1HPETRO-HUNT, L.L.C.Active (A)4,853 ft100%
WOLLAN 152-96-27C-6HPETRO-HUNT, L.L.C.Inactive (IA)4,628 ft100%
CLEAR CREEK 152-96-34B-6HPETRO-HUNT, L.L.C.Active (A)4,419 ft100%
CLEAR CREEK 152-96-34B-5HPETRO-HUNT, L.L.C.Active (A)4,366 ft100%
WOLLAN 152-96-27A-5HPETRO-HUNT, L.L.C.Active (A)4,275 ft100%
WOLLAN 27A-2-2HPETRO-HUNT, L.L.C.Active (A)4,235 ft100%
WOLLAN 27B-2-2HPETRO-HUNT, L.L.C.Inactive (IA)3,936 ft100%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 22330Case 20025Established the spacing unit, 2 wells allowedPETRO- HUNT, LLC
  2. Order 24963Case 22628Pooled all interests in the unitPETRO- HUNT, L.L.C.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

12 other units share a surveyed well with this one; overlapping units are not additive.