Spacing unit · Williams County
3,200-acre Bakken spacing unit
T154N R100W sections 16, 17, 18, 19, 20, 21
Unit facts
- Formation
- Bakken
- Acres
- 3,200
- Type
- Spacing unit
- Land described
- T154N R100W sections 16, 17, 18, 19, 20, 21
- Pool
- Catwalk-Bakken
- Zone
- Zone X
- County
- Williams County
- Surveyed wells inside
- 9
- Most wells operated by
- CONTINENTAL RESOURCES, INC.
- Unit id
dsu-2805a48002f520cc9926- Laterals that still fit (Nov 2026 method)
- 0
- Neighbourhood target density
- 7.47 two-mile laterals per 1,280 acres
- Density drilled so far
- 3.84 per 1,280 acres
Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.
Map
DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.
Wells inside the unit
| Well | Operator | Status | Lateral inside |
|---|---|---|---|
| NASHVILLE 5-21H | CONTINENTAL RESOURCES, INC. | Active (A) | 12,460 ft100% |
| NASHVILLE 4-21H1 | CONTINENTAL RESOURCES, INC. | Active (A) | 12,339 ft100% |
| MARYLAND 5-16H | CONTINENTAL RESOURCES, INC. | Active (A) | 12,207 ft100% |
| NASHVILLE 3-21H | CONTINENTAL RESOURCES, INC. | Active (A) | 12,159 ft100% |
| NASHVILLE 2-21H | CONTINENTAL RESOURCES, INC. | Active (A) | 12,139 ft100% |
| MARYLAND 4-16H1 | CONTINENTAL RESOURCES, INC. | Active (A) | 12,058 ft100% |
| MARYLAND 3-16H | CONTINENTAL RESOURCES, INC. | Active (A) | 11,895 ft100% |
| MARYLAND 2-16H | CONTINENTAL RESOURCES, INC. | Active (A) | 11,586 ft100% |
| GAMMA-STATE 16-15 | CONTINENTAL RESOURCES, INC. | Active (A) | 3,779 ft80% |
Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.
Order history
- Order 26070Case 23728Established the spacing unitCONTINENTAL RESOURCES, INC.
- Order 23687Case 21379Designated the spacing unitCONTINENTAL RESOURCES, INC.
- Order 26102Case 23760Pooled all interests in the unitCONTINENTAL RESOURCES, INC.
- Order 34500Case 31764Designated the spacing unitCONTINENTAL RESOURCES, INC.
Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.
Overlapping units
8 other units share a surveyed well with this one; overlapping units are not additive.
- T154N R101W sections 13, 24 2,560-acre Bakken spacing unit
- T154N R100W sections 16, 21 1,280-acre Bakken spacing unit
- T154N R100W sections 19, 20, 21, 28, 29, 30 3,200-acre Bakken spacing unit
- T154N R100W sections 7, 8, 9, 16, 17, 18 3,200-acre Bakken spacing unit
- T154N R100W sections 19, 20, 21 1,600-acre Bakken spacing unit
- T154N R100W section 16 640-acre Bakken spacing unit
- T154N R100W sections 16, 17, 18 1,600-acre Bakken spacing unit
- T154N R100W sections 15, 16, 21, 22 2,560-acre Bakken spacing unit