BBakken SubsurfaceNorth Dakota well index

Spacing unit · Williams County

2,560-acre Bakken spacing unit

T154N R100W sections 15, 16, 21, 22

Spacing unitCatwalk-Bakken

Unit facts

Formation
Bakken
Acres
2,560
Type
Spacing unit
Land described
T154N R100W sections 15, 16, 21, 22
Pool
Catwalk-Bakken
Zone
Zone IX
County
Williams County
Surveyed wells inside
17
Most wells operated by
CONTINENTAL RESOURCES, INC.
Unit id
dsu-f3b25ee221a2f808320b
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
7.82 two-mile laterals per 1,280 acres
Density drilled so far
4.87 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

JENNER 1-21H1LUCY HANSON 15-22 4HLucy Hanson 15-22 2HLUCY HANSON 15-22 1-HLucy Hanson 15-22 XE 1HLUCY HANSON 15-22 3TFHLUCY HANSON 15-22 5TFHLUCY HANSON 15-22 6HGAMMA-STATE 16-15NASHVILLE 5-21HNASHVILLE 4-21H1MARYLAND 5-16HNASHVILLE 3-21HNASHVILLE 2-21HMARYLAND 4-16H1MARYLAND 3-16HMARYLAND 2-16H1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
JENNER 1-21H1CONTINENTAL RESOURCES, INC.Active (A)13,202 ft100%
LUCY HANSON 15-22 4HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,566 ft100%
Lucy Hanson 15-22 2HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,174 ft100%
LUCY HANSON 15-22 1-HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,028 ft100%
Lucy Hanson 15-22 XE 1HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,876 ft100%
LUCY HANSON 15-22 3TFHDEVON ENERGY WILLISTON, L.L.C.Active (A)9,792 ft100%
LUCY HANSON 15-22 5TFHDEVON ENERGY WILLISTON, L.L.C.Active (A)9,665 ft100%
LUCY HANSON 15-22 6HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,564 ft100%
GAMMA-STATE 16-15CONTINENTAL RESOURCES, INC.Active (A)4,729 ft100%
NASHVILLE 5-21HCONTINENTAL RESOURCES, INC.Active (A)2,167 ft17%
NASHVILLE 4-21H1CONTINENTAL RESOURCES, INC.Active (A)2,048 ft17%
MARYLAND 5-16HCONTINENTAL RESOURCES, INC.Active (A)1,927 ft16%
NASHVILLE 3-21HCONTINENTAL RESOURCES, INC.Active (A)1,868 ft15%
NASHVILLE 2-21HCONTINENTAL RESOURCES, INC.Active (A)1,845 ft15%
MARYLAND 4-16H1CONTINENTAL RESOURCES, INC.Active (A)1,780 ft15%
MARYLAND 3-16HCONTINENTAL RESOURCES, INC.Active (A)1,621 ft14%
MARYLAND 2-16HCONTINENTAL RESOURCES, INC.Active (A)1,319 ft11%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 25009Case 22674Established the spacing unitSTATOIL OIL AND GAS LP
  2. Order 25393Case 23060Pooled all interests in the unitSTATOIL OIL & GAS LP
  3. Order 23687Case 21379Designated the spacing unitCONTINENTAL RESOURCES, INC.
  4. Order 34500Case 31764Designated the spacing unitCONTINENTAL RESOURCES, INC.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

10 other units share a surveyed well with this one; overlapping units are not additive.