BBakken SubsurfaceNorth Dakota well index

Spacing unit · Williams County

1,280-acre Bakken spacing unit

T155N R100W section 36

Spacing unit6 wells allowed · order 35354Stony Creek-Bakken

Unit facts

Formation
Bakken
Acres
1,280
Type
Spacing unit
Land described
T155N R100W section 36
Pool
Stony Creek-Bakken
Zone
Zone IV
County
Williams County
Surveyed wells inside
7
Most wells operated by
Devon Energy
Unit id
dsu-426241279ee97d783957
Wells allowed by the latest linked order
6
Wells assigned to this unit
6
Pending permits inside
0
Balance under the allowance
-1
First linked order
Jul 27, 2009
Laterals that still fit (Nov 2026 method)
2 (1.92 two-mile equivalents)
Neighbourhood target density
8.3 two-mile laterals per 1,280 acres
Density drilled so far
6.63 per 1,280 acres

Room to drill: 2 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

STATE 36-1 1-HSTATE 36-12 6HState 36-1 5HSTATE 36-1 7HSTATE 36-1 4TFHSTATE 36-1 #2TFHSTATE 36-1 3H1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
STATE 36-1 1-HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,572 ft100%
STATE 36-12 6HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,305 ft67%
State 36-1 5HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,099 ft100%
STATE 36-1 7HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,071 ft100%
STATE 36-1 4TFHDEVON ENERGY WILLISTON, L.L.C.Active (A)10,058 ft100%
STATE 36-1 #2TFHDEVON ENERGY WILLISTON, L.L.C.Active (A)9,423 ft100%
STATE 36-1 3HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,305 ft100%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 13276Case 11120Designated the spacing unit
  2. Order 13330Case 11087Established the spacing unitBRIGHAM OIL & GAS, L.P.
  3. Order 14574Case 12322Pooled all interests in the unitBRIGHAM OIL & GAS, L.P.
  4. Order 14591Case 12339Established the spacing unit, 3 wells allowedBRIGHAM OIL & GAS, L.P.
  5. Order 16102Case 13818Established the spacing unit, 4 wells allowed
  6. Order 20408Case 18139Established the spacing unit, 8 wells allowedBRIGHAM OIL & GAS, LP
  7. Order 31932Case 29362Established the spacing unit, 6 wells allowedGRAYSON MILL OPERATING, LLC

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

6 other units share a surveyed well with this one; overlapping units are not additive.