BBakken SubsurfaceNorth Dakota well index

Spacing unit · Williams County

1,280-acre Bakken spacing unit

T154N R100W sections 12, 13

Spacing unit7 wells allowed · order 31932Avoca-Bakken

Unit facts

Formation
Bakken
Acres
1,280
Type
Spacing unit
Land described
T154N R100W sections 12, 13
Pool
Avoca-Bakken
Zone
Zone II
County
Williams County
Surveyed wells inside
9
Most wells operated by
Devon Energy
Unit id
dsu-a9d835dd755e4acb2395
Wells allowed by the latest linked order
7
Wells assigned to this unit
7
Pending permits inside
0
Balance under the allowance
-2
First linked order
Oct 29, 2009
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
8.37 two-mile laterals per 1,280 acres
Density drilled so far
7 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. 1 more would fit the density but not the spacing rule. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

ROSE 12-13 6HROSE 12-13 4TFHROSE 12-13-3HROSE 12-13 7HROSE 12-13 2TFHROSE 12-13 #1HROSE 12-13 5TFHSTATE 36-12 6HKNOSHAUG 14-11 XE #1H1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
ROSE 12-13 6HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,159 ft100%
ROSE 12-13 4TFHDEVON ENERGY WILLISTON, L.L.C.Active (A)9,856 ft100%
ROSE 12-13-3HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,568 ft100%
ROSE 12-13 7HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,565 ft100%
ROSE 12-13 2TFHDEVON ENERGY WILLISTON, L.L.C.Active (A)9,454 ft100%
ROSE 12-13 #1HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,343 ft100%
ROSE 12-13 5TFHDEVON ENERGY WILLISTON, L.L.C.Active (A)8,451 ft100%
STATE 36-12 6HDEVON ENERGY WILLISTON, L.L.C.Active (A)5,066 ft33%
KNOSHAUG 14-11 XE #1HDEVON ENERGY WILLISTON, L.L.C.Active (A)1,737 ft18%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 13740Case 11606Established the spacing unitBRIGHAM OIL & GAS, LP
  2. Order 16301Case 14026Designated the spacing unit, 4 wells allowedCITATION OIL & GAS CORP.
  3. Order 16636Case 14359Established the spacing unit, 4 wells allowed
  4. Order 17535Case 15290Pooled all interests in the unitBRIGHAM OIL & GAS, L.P.
  5. Order 18112Case 15857Designated the spacing unit, 8 wells allowedNEWFIELD PRODUCTION CO.
  6. Order 19523Case 17254Established the spacing unit, 8 wells allowedBRIGHAM OIL & GAS, LP
  7. Order 31932Case 29362Established the spacing unit, 7 wells allowedGRAYSON MILL OPERATING, LLC

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

10 other units share a surveyed well with this one; overlapping units are not additive.