Spacing unit · Mountrail County
640-acre Bakken spacing unit
T150N R92W section 4
Unit facts
- Formation
- Bakken
- Acres
- 640
- Type
- Spacing unit
- Land described
- T150N R92W section 4
- Pool
- Van Hook-Bakken
- Zone
- Zone I
- County
- Mountrail County
- Surveyed wells inside
- 8
- Most wells operated by
- Devon Energy
- Unit id
dsu-4a99db473785b9252cec- Wells allowed by the latest linked order
- 1
- Wells assigned to this unit
- 2
- Pending permits inside
- 0
- Balance under the allowance
- -7
- First linked order
- Oct 19, 2011
- Review note
- wells_predate_linked_orders
- Laterals that still fit (Nov 2026 method)
- 0
- Neighbourhood target density
- 9.18 two-mile laterals per 1,280 acres
- Density drilled so far
- 7.16 per 1,280 acres
Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. 2 more would fit the density but not the spacing rule. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.
Map
DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.
Wells inside the unit
| Well | Operator | Status | Lateral inside |
|---|---|---|---|
| ROGGENBUCK 4-9HY | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 5,166 ft50% |
| ROGGENBUCK 4-9HX | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 5,139 ft50% |
| BRUNSELL 9-4HZ | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 5,057 ft50% |
| ROGGENBUCK 4-9HW | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 5,042 ft50% |
| VAN HOOK - R/S 16-4H | DEVON ENERGY WILLISTON, L.L.C. | Plugged and abandoned (PA) | 5,027 ft100% |
| ROGGENBUCK 4-9HA | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 5,016 ft50% |
| VAN HOOK R/S 4HC | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 4,191 ft100% |
| BRUNSELL 9-4HB | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 2,532 ft38% |
Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.
Order history
- Order 17491Case 15246Pooled all interests in the unitDAKOTA-3 E&P CO., LLC
- Order 17851Case 15605Listed the unit in a pool zone table, 3 wells allowedDAKOTA-3 E&P CO., LLC
- Order 18233Case 15971Established the spacing unit, 3 wells allowedDAKOTA-3 E&P CO., LLC
- Order 22209Case 19902Established the spacing unit, 1 well allowedWPX ENERGY WILLISTON, LLC
Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.
Overlapping units
3 other units share a surveyed well with this one; overlapping units are not additive.
- T150N R92W sections 4, 9 1,280-acre Bakken spacing unit
- T150N R92W sections 3, 4, 9, 10 2,560-acre Bakken spacing unit
- T150N R92W section 9 640-acre Bakken spacing unit