BBakken SubsurfaceNorth Dakota well index

Spacing unit · Mountrail County

640-acre Bakken spacing unit

T150N R92W section 9

Spacing unit1 wells allowed · order 22209Van Hook-Bakken

Unit facts

Formation
Bakken
Acres
640
Type
Spacing unit
Land described
T150N R92W section 9
Pool
Van Hook-Bakken
Zone
Zone I
County
Mountrail County
Surveyed wells inside
8
Most wells operated by
Devon Energy
Unit id
dsu-ef75477b3ddccd7bf087
Wells allowed by the latest linked order
1
Wells assigned to this unit
1
Pending permits inside
0
Balance under the allowance
-7
First linked order
Oct 19, 2011
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
9.18 two-mile laterals per 1,280 acres
Density drilled so far
7.37 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. 2 more would fit the density but not the spacing rule. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

BRUNSELL 16-9HROGGENBUCK 4-9HXROGGENBUCK 4-9HAROGGENBUCK 4-9HWROGGENBUCK 4-9HYBRUNSELL 9-4HZBRUNSELL 9-4HBLARCH 10-3HE1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
BRUNSELL 16-9HDEVON ENERGY WILLISTON, L.L.C.Inactive (IA)7,028 ft100%
ROGGENBUCK 4-9HXDEVON ENERGY WILLISTON, L.L.C.Active (A)5,060 ft50%
ROGGENBUCK 4-9HADEVON ENERGY WILLISTON, L.L.C.Active (A)5,059 ft50%
ROGGENBUCK 4-9HWDEVON ENERGY WILLISTON, L.L.C.Active (A)5,059 ft50%
ROGGENBUCK 4-9HYDEVON ENERGY WILLISTON, L.L.C.Active (A)5,055 ft50%
BRUNSELL 9-4HZDEVON ENERGY WILLISTON, L.L.C.Active (A)5,031 ft50%
BRUNSELL 9-4HBDEVON ENERGY WILLISTON, L.L.C.Active (A)4,136 ft62%
LARCH 10-3HEDEVON ENERGY WILLISTON, L.L.C.Active (A)2,180 ft22%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 17492Case 15247Pooled all interests in the unitDAKOTA-3 E&P CO., LLC
  2. Order 17851Case 15605Listed the unit in a pool zone table, 3 wells allowedDAKOTA-3 E&P CO., LLC
  3. Order 18093Case 15838Established the spacing unit, 3 wells allowedDAKOTA-3 E&P CO., LLC
  4. Order 22209Case 19902Established the spacing unit, 1 well allowedWPX ENERGY WILLISTON, LLC

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

5 other units share a surveyed well with this one; overlapping units are not additive.