BBakken SubsurfaceNorth Dakota well index

Spacing unit · McKenzie County

1,280-acre Bakken spacing unit

T150N R97W sections 16, 21

Spacing unit14 wells allowed · order 34449Siverston-Bakken

Unit facts

Formation
Bakken
Acres
1,280
Type
Spacing unit
Land described
T150N R97W sections 16, 21
Pool
Siverston-Bakken
Zone
Zone X
County
McKenzie County
Surveyed wells inside
13
Most wells operated by
Devon Energy
Unit id
dsu-4d557f790e0bfd64dfd6
Wells allowed by the latest linked order
14
Wells assigned to this unit
11
Pending permits inside
0
Balance under the allowance
+1
First linked order
Aug 21, 2008
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
9.67 two-mile laterals per 1,280 acres
Density drilled so far
12.27 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

NEWMAN 150-97-21-16-13HNEWMAN 150-97-21-16-5HNEWMAN 150-97-21-16-7HNEWMAN 150-97-21-16-14HNEWMAN 150-97-21-16-6HRNEWMAN 150-97-21-16-2HNEWMAN 150-97-21-16-6HNEWMAN 150-97-21-16-1HNEWMAN 150-97-21-16-12HNEWMAN 150-97-21-16-15HNEWMAN 150-97-21-16-8HLWSTENEHJEM 44-21HLUND 41X-17HXE1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
NEWMAN 150-97-21-16-13HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,910 ft100%
NEWMAN 150-97-21-16-5HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,135 ft100%
NEWMAN 150-97-21-16-7HDEVON ENERGY WILLISTON, L.L.C.Plugged and abandoned (PA)10,100 ft100%
NEWMAN 150-97-21-16-14HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,088 ft100%
NEWMAN 150-97-21-16-6HRDEVON ENERGY WILLISTON, L.L.C.Active (A)10,076 ft100%
NEWMAN 150-97-21-16-2HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,066 ft100%
NEWMAN 150-97-21-16-6HDEVON ENERGY WILLISTON, L.L.C.Plugged and abandoned (PA)10,052 ft100%
NEWMAN 150-97-21-16-1HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,050 ft100%
NEWMAN 150-97-21-16-12HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,011 ft100%
NEWMAN 150-97-21-16-15HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,814 ft100%
NEWMAN 150-97-21-16-8HLWDEVON ENERGY WILLISTON, L.L.C.Active (A)9,725 ft96%
STENEHJEM 44-21HDEVON ENERGY WILLISTON, L.L.C.Inactive (IA)9,307 ft100%
LUND 41X-17HXEXTO ENERGY INCActive (A)8,694 ft87%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 12191Case 10320Established the spacing unitENCORE OPERATING, L.P.
  2. Order 12378Case 10475Designated the spacing unitST. MARY LAND & EXPL. CO.
  3. Order 17062Case 14786Designated the spacing unitNEWFIELD PRODUCTION CO.
  4. Order 18104Case 15849Established the spacing unit, 7 wells allowedDENBURY ONSHORE, LLC
  5. Order 21900Case 19594Designated the spacing unit, 10 wells allowedSM ENERGY CO.
  6. Order 23012Case 20707Established the spacing unit, 10 wells allowedXTO ENERGY INC.
  7. Order 30062Case 27618Designated the spacing unit, 14 wells allowedXTO ENERGY INC.
  8. Order 30524Case 28071Established the spacing unit, 14 wells allowedNEWFIELD PRODUCTION CO.
  9. Order 30680Case 28227Pooled all interests in the unitNEWFIELD PRODUCTION CO.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

5 other units share a surveyed well with this one; overlapping units are not additive.