BBakken SubsurfaceNorth Dakota well index

Spacing unit · McKenzie County

1,280-acre Bakken spacing unit

T152N R97W sections 25, 36

Spacing unit11 wells allowed · order 33063Westberg-Bakken

Unit facts

Formation
Bakken
Acres
1,280
Type
Spacing unit
Land described
T152N R97W sections 25, 36
Pool
Westberg-Bakken
Zone
Zone VII
County
McKenzie County
Surveyed wells inside
12
Most wells operated by
Devon Energy
Unit id
dsu-6b6ea54e953db7914f2e
Wells allowed by the latest linked order
11
Wells assigned to this unit
9
Pending permits inside
0
Balance under the allowance
-1
First linked order
Dec 20, 2010
Laterals that still fit (Nov 2026 method)
1 (0.95 two-mile equivalents)
Neighbourhood target density
10.09 two-mile laterals per 1,280 acres
Density drilled so far
9.52 per 1,280 acres

Room to drill: 1 lateral still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

CLEAR CREEK FEDERAL 152-97-36-25-6HCLEAR CREEK FEDERAL 152-97-36-25-12HCLEAR CREEK FEDERAL 152-97-36-25-7HCLEAR CREEK FEDERAL 152-97-36-25-13HCLEAR CREEK FEDERAL 152-97-36-25-8HCLEAR CREEK FEDERAL 152-97-36-25-14HCLEAR CREEK FEDERAL 152-97-36-25-5HCLEAR CREEK FEDERAL 152-97-36-25-3HCLEAR CREEK FEDERAL 152-97-36-25-2HCLEAR CREEK STATE 1-36HCLEAR CREEK FEDERAL 1-25HOLSON 152-96-30-31-4HLW1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
CLEAR CREEK FEDERAL 152-97-36-25-6HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,087 ft100%
CLEAR CREEK FEDERAL 152-97-36-25-12HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,079 ft100%
CLEAR CREEK FEDERAL 152-97-36-25-7HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,066 ft100%
CLEAR CREEK FEDERAL 152-97-36-25-13HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,050 ft100%
CLEAR CREEK FEDERAL 152-97-36-25-8HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,027 ft100%
CLEAR CREEK FEDERAL 152-97-36-25-14HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,025 ft100%
CLEAR CREEK FEDERAL 152-97-36-25-5HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,993 ft100%
CLEAR CREEK FEDERAL 152-97-36-25-3HDEVON ENERGY WILLISTON, L.L.C.Abandoned (AB)9,601 ft100%
CLEAR CREEK FEDERAL 152-97-36-25-2HDEVON ENERGY WILLISTON, L.L.C.Abandoned (AB)9,490 ft100%
CLEAR CREEK STATE 1-36HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,026 ft100%
CLEAR CREEK FEDERAL 1-25HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,015 ft100%
OLSON 152-96-30-31-4HLWDEVON ENERGY WILLISTON, L.L.C.Active (A)3,421 ft33%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 14819Case 12560Designated the spacing unit, 2 wells allowedNEWFIELD PRODUCTION CO.
  2. Order 15039Case 12776Established the spacing unit, 2 wells allowedNEWFIELD PRODUCTION CO.
  3. Order 18840Case 16574Established the spacing unit, 6 wells allowedNEWFIELD PRODUCTION CO.
  4. Order 20815Case 18529Pooled all interests in the unitNEWFIELD PRODUCTION CO.
  5. Order 24413Case 22079Designated the spacing unit, 6 wells allowedHESS BAKKEN INVESTMENTS II, LLC
  6. Order 25072Case 22737Established the spacing unit, 7 wells allowedNEWFIELD PRODUCTION CO.
  7. Order 23722Case 21381Designated the spacing unit, 7 wells allowedCONTINENTAL RESOURCES, INC.
  8. Order 31532Case 28981Established the spacing unit, 11 wells allowedOVINTIV PRODUCTION INC.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

8 other units share a surveyed well with this one; overlapping units are not additive.