Spacing unit · McKenzie County
2,560-acre Bakken spacing unit
T152N R97W sections 25, 36
Unit facts
- Formation
- Bakken
- Acres
- 2,560
- Type
- Spacing unit
- Land described
- T152N R97W sections 25, 36
- Pool
- Westberg-Bakken
- Zone
- Zone XII
- County
- McKenzie County
- Surveyed wells inside
- 23
- Most wells operated by
- Devon Energy
- Unit id
dsu-ae2dedaf0d61dbff7b8a- Wells allowed by the latest linked order
- 2
- Wells assigned to this unit
- 1
- Pending permits inside
- 0
- Balance under the allowance
- -21
- First linked order
- Aug 12, 2014
- Laterals that still fit (Nov 2026 method)
- 0
- Neighbourhood target density
- 10.1 two-mile laterals per 1,280 acres
- Density drilled so far
- 10.1 per 1,280 acres
Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.
Map
DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.
Wells inside the unit
| Well | Operator | Status | Lateral inside |
|---|---|---|---|
| OLSON 152-96-30-31-6H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,544 ft100% |
| OLSON 152-96-30-31-3H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,359 ft100% |
| OLSON 152-96-30-31-4HLW | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,283 ft100% |
| OLSON 152-96-30-31-16H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,234 ft100% |
| OLSON 152-96-30-31-2H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,143 ft100% |
| OLSON 152-96-30-31-10H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,097 ft100% |
| CLEAR CREEK FEDERAL 152-97-36-25-6H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,087 ft100% |
| CLEAR CREEK FEDERAL 152-97-36-25-12H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,079 ft100% |
| CLEAR CREEK FEDERAL 152-97-36-25-7H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,066 ft100% |
| CLEAR CREEK FEDERAL 152-97-36-25-13H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,050 ft100% |
| CLEAR CREEK FEDERAL 152-97-36-25-8H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,027 ft100% |
| CLEAR CREEK FEDERAL 152-97-36-25-14H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,025 ft100% |
| OLSON 152-96-30-31-12H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,022 ft100% |
| CLEAR CREEK FEDERAL 152-97-36-25-5H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,993 ft100% |
| OLSON 152-96-30-31-1H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,934 ft100% |
| OLSON 152-96-30-31-11H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,758 ft100% |
| CLEAR CREEK FEDERAL 152-97-36-25-3H | DEVON ENERGY WILLISTON, L.L.C. | Abandoned (AB) | 9,601 ft100% |
| CLEAR CREEK FEDERAL 152-97-36-25-2H | DEVON ENERGY WILLISTON, L.L.C. | Abandoned (AB) | 9,490 ft100% |
| OLSON 152-96-30-31-13HLW | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 8,641 ft88% |
| OLSON 1-30H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 5,214 ft100% |
| HAROLD 1-31H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 4,664 ft100% |
| CLEAR CREEK STATE 1-36H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 4,026 ft100% |
| CLEAR CREEK FEDERAL 1-25H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 4,015 ft100% |
Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.
Order history
- Order 24863Case 22529Established the spacing unit, 1 well allowedNEWFIELD PRODUCTION CO.
- Order 25068Case 22733Pooled all interests in the unitNEWFIELD PRODUCTION CO.
- Order 23722Case 21381Designated the spacing unitCONTINENTAL RESOURCES, INC.
- Order 31199Case 28656Listed the unit in a pool zone table, 2 wells allowedOVINTIV PRODUCTION INC.
- Order 31532Case 28981Designated the spacing unitOVINTIV PRODUCTION INC.
- Order 31818Case 29249Established the spacing unit, 2 wells allowedOVINTIV PRODUCTION INC.
Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.
Overlapping units
11 other units share a surveyed well with this one; overlapping units are not additive.
- T152N R96W sections 30, 31 1,280-acre Bakken spacing unit
- T152N R96W sections 29, 30, 31, 32 2,560-acre Bakken spacing unit
- T152N R96W sections 28, 29, 32, 33 2,560-acre Bakken spacing unit
- T152N R96W sections 29, 32 1,280-acre Bakken spacing unit
- T152N R97W section 25 640-acre Bakken spacing unit
- T152N R97W sections 25, 36 1,280-acre Bakken spacing unit
- T152N R96W section 31 640-acre Bakken spacing unit
- T152N R97W sections 25, 26, 35, 36 2,560-acre Bakken spacing unit
- T152N R96W section 30 640-acre Bakken spacing unit
- T152N R97W section 36 640-acre Bakken spacing unit
- T152N R96W section 29 640-acre Bakken spacing unit