BBakken SubsurfaceNorth Dakota well index

Spacing unit · McKenzie County

3,840-acre Bakken spacing unit

T153N R96W sections 15, 16, 21, 22, 27, 28

Spacing unitSand Creek-Bakken

Unit facts

Formation
Bakken
Acres
3,840
Type
Spacing unit
Land described
T153N R96W sections 15, 16, 21, 22, 27, 28
Pool
Sand Creek-Bakken
Zone
Zone XXIII
County
McKenzie County
Surveyed wells inside
33
Most wells operated by
DEVON ENERGY WILLISTON, L.L.C.
Unit id
dsu-753a6500cb007c331280
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
9.53 two-mile laterals per 1,280 acres
Density drilled so far
7.56 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. 1 more would fit the density but not the spacing rule. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

SKAAR FEDERAL 153-96-28-21-12HHELSINGBORG FEDERAL 153-96-22-27-2HHELSINGBORG FEDERAL 153-96-27-22-11HSKAAR FEDERAL 153-96-28-21-11HSKAAR FEDERAL 153-96-28-21-5HHELSINGBORG FEDERAL 153-96-27-22-4HSKAAR FEDERAL 153-96-28-21-4HHELSINGBORG FEDERAL 153-96-27-22-12HHELSINGBORG FEDERAL 153-96-22-27-3HHELSINGBORG FEDERAL 153-96-27-22-13HSAND CREEK FEDERAL 153-96-21-28-10HHELSINGBORG FEDERAL 153-96-22-27-10HSAND CREEK FEDERAL 153-96-21-28-3HSAND CREEK FEDERAL 153-96-21-28-2HSAND CREEK FEDERAL 153-96-21-28-13HLWTARPON FEDERAL 34-20TFHUSAND CREEK 21-10SHHARLEY FEDERAL 24X-15EOLD ARCHES 14-35MBH ULWHARLEY FEDERAL 24X-15ASAND CREEK STATE 153-96-16-11HSAND CREEK STATE 153-96-16-10HSAND CREEK STATE 153-96-16-3HSAND CREEK FEDERAL 1-21HSAND CREEK STATE 153-96-16-2HSAND CREEK STATE 153-96-16-4HSAND CREEK STATE 153-96-16-12HSAND CREEK STATE 1-16HHARLEY FEDERAL 24X-15BHARLEY FEDERAL 24X-15FSAND CREEK FEDERAL 1-27HAHELSINGBORG 1-22HALICE FEDERAL 1-28H1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
SKAAR FEDERAL 153-96-28-21-12HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,305 ft100%
HELSINGBORG FEDERAL 153-96-22-27-2HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,270 ft100%
HELSINGBORG FEDERAL 153-96-27-22-11HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,265 ft100%
SKAAR FEDERAL 153-96-28-21-11HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,233 ft100%
SKAAR FEDERAL 153-96-28-21-5HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,138 ft100%
HELSINGBORG FEDERAL 153-96-27-22-4HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,086 ft100%
SKAAR FEDERAL 153-96-28-21-4HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,069 ft100%
HELSINGBORG FEDERAL 153-96-27-22-12HDEVON ENERGY WILLISTON, L.L.C.Abandoned (AB)10,022 ft100%
HELSINGBORG FEDERAL 153-96-22-27-3HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,975 ft100%
HELSINGBORG FEDERAL 153-96-27-22-13HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,907 ft100%
SAND CREEK FEDERAL 153-96-21-28-10HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,886 ft100%
HELSINGBORG FEDERAL 153-96-22-27-10HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,859 ft100%
SAND CREEK FEDERAL 153-96-21-28-3HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,827 ft100%
SAND CREEK FEDERAL 153-96-21-28-2HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,772 ft100%
SAND CREEK FEDERAL 153-96-21-28-13HLWDEVON ENERGY WILLISTON, L.L.C.Active (A)9,726 ft100%
TARPON FEDERAL 34-20TFHUWHITING OIL AND GAS CORPORATIONActive (A)8,472 ft57%
SAND CREEK 21-10SHXTO ENERGY INCActive (A)5,869 ft59%
HARLEY FEDERAL 24X-15EXTO ENERGY INCActive (A)5,212 ft51%
OLD ARCHES 14-35MBH ULWBURLINGTON RESOURCES OIL & GAS COMPANY LPActive (A)5,092 ft52%
HARLEY FEDERAL 24X-15AXTO ENERGY INCActive (A)4,982 ft50%
SAND CREEK STATE 153-96-16-11HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,799 ft100%
SAND CREEK STATE 153-96-16-10HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,743 ft100%
SAND CREEK STATE 153-96-16-3HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,707 ft100%
SAND CREEK FEDERAL 1-21HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,621 ft100%
SAND CREEK STATE 153-96-16-2HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,573 ft100%
SAND CREEK STATE 153-96-16-4HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,570 ft100%
SAND CREEK STATE 153-96-16-12HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,488 ft100%
SAND CREEK STATE 1-16HDEVON ENERGY WILLISTON, L.L.C.Plugged and abandoned (PA)4,477 ft100%
HARLEY FEDERAL 24X-15BXTO ENERGY INCActive (A)4,441 ft47%
HARLEY FEDERAL 24X-15FXTO ENERGY INCActive (A)4,390 ft47%
SAND CREEK FEDERAL 1-27HADEVON ENERGY WILLISTON, L.L.C.Active (A)4,384 ft100%
HELSINGBORG 1-22HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,133 ft100%
ALICE FEDERAL 1-28HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,048 ft100%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 31976Case 29405Established the spacing unitOVINTIV PRODUCTION INC.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

22 other units share a surveyed well with this one; overlapping units are not additive.