BBakken SubsurfaceNorth Dakota well index

Spacing unit · McKenzie County

2,560-acre Bakken spacing unit

T153N R96W sections 3, 4, 9, 10

Spacing unit2 wells allowed · order 31977Sand Creek-Bakken

Unit facts

Formation
Bakken
Acres
2,560
Type
Spacing unit
Land described
T153N R96W sections 3, 4, 9, 10
Pool
Sand Creek-Bakken
Zone
Zone XIX
County
McKenzie County
Surveyed wells inside
20
Most wells operated by
Devon Energy
Unit id
dsu-d622d1660230a049326a
Wells allowed by the latest linked order
2
Wells assigned to this unit
1
Pending permits inside
0
Balance under the allowance
-18
First linked order
Jan 30, 2020
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
8.86 two-mile laterals per 1,280 acres
Density drilled so far
7.45 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

SORENSON FEDERAL 153-96-9-4-10HSORENSON FEDERAL 153-96-9-4-6HLWSORENSON FEDERAL 153-96-4-9-1HSORENSON FEDERAL 153-96-4-9-2HSORENSON FEDERAL 153-96-9-4-3HSORENSON FEDERAL 153-96-9-4-4HSORENSON FEDERAL 153-96-9-4-14HSORENSON FEDERAL 153-96-9-4-5HSORENSON FEDERAL 153-96-9-4-13HSORENSON FEDERAL 153-96-9-4-11HSORENSON FEDERAL 153-96-9-4-12HPITTSBURGH FEDERAL 153-96-3-2HPITTSBURGH FEDERAL 153-96-3-11HHARLEY FEDERAL 24X-15AHARLEY FEDERAL 24X-15EHARLEY FEDERAL 24X-15BHARLEY FEDERAL 24X-15FPITTSBURGH 1-3HPITTSBURGH FEDERAL 153-96-3-3HSAND CREEK 21-10SH1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
SORENSON FEDERAL 153-96-9-4-10HDEVON ENERGY WILLISTON, L.L.C.Active (A)11,969 ft100%
SORENSON FEDERAL 153-96-9-4-6HLWDEVON ENERGY WILLISTON, L.L.C.Active (A)11,409 ft100%
SORENSON FEDERAL 153-96-4-9-1HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,268 ft100%
SORENSON FEDERAL 153-96-4-9-2HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,228 ft100%
SORENSON FEDERAL 153-96-9-4-3HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,132 ft100%
SORENSON FEDERAL 153-96-9-4-4HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,079 ft100%
SORENSON FEDERAL 153-96-9-4-14HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,065 ft100%
SORENSON FEDERAL 153-96-9-4-5HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,020 ft100%
SORENSON FEDERAL 153-96-9-4-13HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,984 ft100%
SORENSON FEDERAL 153-96-9-4-11HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,980 ft100%
SORENSON FEDERAL 153-96-9-4-12HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,537 ft100%
PITTSBURGH FEDERAL 153-96-3-2HDEVON ENERGY WILLISTON, L.L.C.Active (A)5,196 ft100%
PITTSBURGH FEDERAL 153-96-3-11HDEVON ENERGY WILLISTON, L.L.C.Active (A)5,092 ft100%
HARLEY FEDERAL 24X-15AXTO ENERGY INCActive (A)5,038 ft50%
HARLEY FEDERAL 24X-15EXTO ENERGY INCActive (A)5,032 ft49%
HARLEY FEDERAL 24X-15BXTO ENERGY INCActive (A)5,026 ft53%
HARLEY FEDERAL 24X-15FXTO ENERGY INCActive (A)5,020 ft53%
PITTSBURGH 1-3HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,663 ft100%
PITTSBURGH FEDERAL 153-96-3-3HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,276 ft100%
SAND CREEK 21-10SHXTO ENERGY INCActive (A)4,084 ft41%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 30398Case 27946Pooled all interests in the unitNEWFIELD PRODUCTION CO.
  2. Order 30447Case 27994Designated the spacing unit, 2 wells allowedWHITING OIL AND GAS CORP.
  3. Order 30505Case 28052Established the spacing unit, 2 wells allowedNEWFIELD PRODUCTION CO.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

6 other units share a surveyed well with this one; overlapping units are not additive.