BBakken SubsurfaceNorth Dakota well index

Spacing unit · Dunn County

1,280-acre Bakken spacing unit

T149N R93W sections 24, 25

Spacing unit12 wells allowed · order 33767Mandaree-Bakken

Unit facts

Formation
Bakken
Acres
1,280
Type
Spacing unit
Land described
T149N R93W sections 24, 25
Pool
Mandaree-Bakken
Zone
Zone XVI
County
Dunn County
Surveyed wells inside
10
Most wells operated by
Devon Energy
Unit id
dsu-a18604c334d053f1207a
Wells allowed by the latest linked order
12
Wells assigned to this unit
9
Pending permits inside
0
Balance under the allowance
+2
First linked order
Feb 19, 2010
Laterals that still fit (Nov 2026 method)
1 (0.95 two-mile equivalents)
Neighbourhood target density
9.3 two-mile laterals per 1,280 acres
Density drilled so far
8.71 per 1,280 acres

Room to drill: 1 lateral still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

SKUNK CREEK 2-24-25-15HSKUNK CREEK 4-24-25-13H3SKUNK CREEK 3-24-25-14H3SKUNK CREEK 3-24-25-14HBSKUNK CREEK 3-24-25-14HASKUNK CREEK 3-24-25-13HSKUNK CREEK 4-24-26-16HUSKUNK CREEK 2-24-25-16HSKUNK CREEK 1-24-25-16H3Closer 149-92-19C-18H-LL1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
SKUNK CREEK 2-24-25-15HDEVON ENERGY WILLISTON, L.L.C.Plugged and abandoned (PA)10,381 ft100%
SKUNK CREEK 4-24-25-13H3DEVON ENERGY WILLISTON, L.L.C.Active (A)9,877 ft100%
SKUNK CREEK 3-24-25-14H3DEVON ENERGY WILLISTON, L.L.C.Active (A)9,827 ft100%
SKUNK CREEK 3-24-25-14HBDEVON ENERGY WILLISTON, L.L.C.Active (A)9,810 ft100%
SKUNK CREEK 3-24-25-14HADEVON ENERGY WILLISTON, L.L.C.Active (A)9,802 ft100%
SKUNK CREEK 3-24-25-13HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,745 ft100%
SKUNK CREEK 4-24-26-16HUDEVON ENERGY WILLISTON, L.L.C.Active (A)9,720 ft100%
SKUNK CREEK 2-24-25-16HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,641 ft100%
SKUNK CREEK 1-24-25-16H3DEVON ENERGY WILLISTON, L.L.C.Active (A)9,191 ft100%
Closer 149-92-19C-18H-LLENERPLUS RESOURCES USA CORPORATIONActive (A)2,904 ft29%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 14184Case 11986Established the spacing unit, 1 well allowedKODIAK OIL & GAS (USA) INC.
  2. Order 14184Case 11986Designated the spacing unitKODIAK OIL & GAS (USA) INC.
  3. Order 14398Case 12146Designated the spacing unit
  4. Order 14674Case 12418Designated the spacing unit, 4 wells allowedEOG RESOURCES, INC.
  5. Order 14999Case 12738Established the spacing unit, 4 wells allowedKODIAK OIL & GAS (USA) INC.
  6. Order 16570Case 14294Pooled all interests in the unitKODIAK OIL & GAS (USA) INC.
  7. Order 22756Case 20450Established the spacing unit, 10 wells allowedKODIAK OIL & GAS (USA) INC.
  8. Order 25915Case 23575Established the spacing unit, 12 wells allowedWHITING OIL AND GAS CORP.
  9. Order 28530Case 26117Designated the spacing unit, 11 wells allowedENERPLUS RESOURCES (USA) CORP.
  10. Order 28530Case 26117Listed the unit in a pool zone table, 12 wells allowedENERPLUS RESOURCES (USA) CORP.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

11 other units share a surveyed well with this one; overlapping units are not additive.