BBakken SubsurfaceNorth Dakota well index

Spacing unit · Williams County

2,560-acre Bakken spacing unit

T154N R96W sections 2, 3, 10, 11

Spacing unit2 wells allowed · order 29165Capa-Bakken

Unit facts

Formation
Bakken
Acres
2,560
Type
Spacing unit
Land described
T154N R96W sections 2, 3, 10, 11
Pool
Capa-Bakken
Zone
Zone XI
County
Williams County
Surveyed wells inside
17
Most wells operated by
XTO Energy
Unit id
dsu-cab5a3c01e882a5dfd29
Wells allowed by the latest linked order
2
Wells assigned to this unit
0
Pending permits inside
0
Balance under the allowance
-15
First linked order
Jan 23, 2015
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
8.65 two-mile laterals per 1,280 acres
Density drilled so far
8.47 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

GBU HARNEY 41X-2GBU SOPHIA 44X-10E-NGBU WAYNE 34X-34FGBU APOLLO FEDERAL 14X-12D-NGBU SOPHIA 44X-10A-NGBU APOLLO FEDERAL 14X-12H-NGBU APOLLO FEDERAL 14X-12C-NGBU SOPHIA FEDERAL 44X-10B-NGBU SOPHIA FEDERAL 44X-10F-NGBU ATHENA 31X-3CGBU ATHENA 31X-3FGBU ATHENA 31X-3GGBU ATHENA 31X-3DGBU KELLY 41X-3GBU ATHENA 31X-3AGBU ATHENA 31X-3HHM HOVE 34X-33H1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
GBU HARNEY 41X-2XTO ENERGY INCInactive (IA)23,418 ft100%
GBU SOPHIA 44X-10E-NXTO ENERGY INCDrilling (DRL)10,640 ft100%
GBU WAYNE 34X-34FXTO ENERGY INCInactive (IA)10,471 ft100%
GBU APOLLO FEDERAL 14X-12D-NXTO ENERGY INCDrilling (DRL)10,394 ft100%
GBU SOPHIA 44X-10A-NXTO ENERGY INCDrilling (DRL)10,370 ft100%
GBU APOLLO FEDERAL 14X-12H-NXTO ENERGY INCDrilling (DRL)10,332 ft100%
GBU APOLLO FEDERAL 14X-12C-NXTO ENERGY INCDrilling (DRL)10,329 ft100%
GBU SOPHIA FEDERAL 44X-10B-NXTO ENERGY INCDrilling (DRL)10,307 ft100%
GBU SOPHIA FEDERAL 44X-10F-NXTO ENERGY INCDrilling (DRL)10,276 ft100%
GBU ATHENA 31X-3CXTO ENERGY INCDrilling (DRL)10,160 ft67%
GBU ATHENA 31X-3FXTO ENERGY INCDrilling (DRL)10,105 ft67%
GBU ATHENA 31X-3GXTO ENERGY INCDrilling (DRL)10,089 ft66%
GBU ATHENA 31X-3DXTO ENERGY INCDrilling (DRL)10,060 ft66%
GBU KELLY 41X-3XTO ENERGY INCTemporarily abandoned (TA)10,051 ft100%
GBU ATHENA 31X-3AXTO ENERGY INCDrilling (DRL)10,046 ft68%
GBU ATHENA 31X-3HXTO ENERGY INCDrilling (DRL)10,006 ft68%
HM HOVE 34X-33HCONTINENTAL RESOURCES, INC.Active (A)1,560 ft14%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 23587Case 21283Established the spacing unitXTO ENERGY INC.
  2. Order 24625Case 22292Designated the spacing unitHESS BAKKEN INVESTMENTS II, LLC
  3. Order 26139Case 23798Designated the spacing unitLIBERTY RESOURCES MANAGEMENT CO., LLC
  4. Order 26286Case 23943Established the spacing unit, 2 wells allowedXTO ENERGY INC.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

6 other units share a surveyed well with this one; overlapping units are not additive.