BBakken SubsurfaceNorth Dakota well index

Spacing unit · Mountrail County

1,280-acre Bakken spacing unit

T154N R92W sections 26, 35

Spacing unit11 wells allowed · order 35866Sanish-Bakken

Unit facts

Formation
Bakken
Acres
1,280
Type
Spacing unit
Land described
T154N R92W sections 26, 35
Pool
Sanish-Bakken
Zone
Zone XXII
County
Mountrail County
Surveyed wells inside
12
Most wells operated by
Chord / Enerplus / Oasis / Whiting
Unit id
dsu-ebaf08bcd22e04c41764
Wells allowed by the latest linked order
11
Wells assigned to this unit
9
Pending permits inside
0
Balance under the allowance
-1
First linked order
Jan 23, 2008
Laterals that still fit (Nov 2026 method)
1 (0.96 two-mile equivalents)
Neighbourhood target density
8.96 two-mile laterals per 1,280 acres
Density drilled so far
8.31 per 1,280 acres

Room to drill: 1 lateral still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

DANITA TTT 21-26TFHDexter TTT 11-26-2HTTT RANCH 11-26HConnor TTT 11-26-1HTTT RANCH 21-26HREMINGTON TTT 41-26TFHBRITTANY TTT 13-26TFHMATT TTT 13-26HSAVANNAH TTT 41-26HKannianen 11-5-3HUIsabella TTT 41-26HUIVERSON 11-14HU1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
DANITA TTT 21-26TFHWHITING OIL AND GAS CORPORATIONActive (A)11,142 ft100%
Dexter TTT 11-26-2HWHITING OIL AND GAS CORPORATIONActive (A)9,896 ft100%
TTT RANCH 11-26HWHITING OIL AND GAS CORPORATIONPlugged and abandoned (PA)9,827 ft100%
Connor TTT 11-26-1HWHITING OIL AND GAS CORPORATIONActive (A)9,688 ft100%
TTT RANCH 21-26HWHITING OIL AND GAS CORPORATIONActive (A)9,493 ft100%
REMINGTON TTT 41-26TFHWHITING OIL AND GAS CORPORATIONActive (A)8,310 ft100%
BRITTANY TTT 13-26TFHWHITING OIL AND GAS CORPORATIONActive (A)7,062 ft100%
MATT TTT 13-26HWHITING OIL AND GAS CORPORATIONActive (A)7,026 ft100%
SAVANNAH TTT 41-26HWHITING OIL AND GAS CORPORATIONActive (A)6,863 ft100%
Kannianen 11-5-3HUWHITING OIL AND GAS CORPORATIONActive (A)5,196 ft34%
Isabella TTT 41-26HUWHITING OIL AND GAS CORPORATIONActive (A)1,827 ft19%
IVERSON 11-14HUWHITING OIL AND GAS CORPORATIONActive (A)1,740 ft15%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 11593Case 9850Established the spacing unitWHITING OIL & GAS CORP.
  2. Order 11594Case 9851Pooled all interests in the unitWHITING OIL & GAS CORP.
  3. Order 11676Case 9913Designated the spacing unit
  4. Order 13769Case 11628Designated the spacing unitWHITING OIL & GAS CORP.
  5. Order 13904Case 11743Designated the spacing unit, 4 wells allowedWHITING OIL & GAS CORP.
  6. Order 15653Case 13377Established the spacing unit, 6 wells allowedWHITING OIL & GAS CORP.
  7. Order 22761Case 20455Designated the spacing unit, 6 wells allowedOASIS PETROLEUM NORTH AMERICA LLC
  8. Order 22755Case 20449Established the spacing unit, 11 wells allowedWHITING OIL AND GAS CORP.
  9. Order 24251Case 21918Designated the spacing unit, 11 wells allowedOASIS PETROLEUM NORTH AMERICA LLC
  10. Order 31168Case 28626Designated the spacing unit, 9 wells allowedWHITING OIL AND GAS CORP.
  11. Order 31168Case 28626Listed the unit in a pool zone table, 11 wells allowedWHITING OIL AND GAS CORP.
  12. Order 31169Case 28627Designated the spacing unit, 9 wells allowedWHITING OIL AND GAS CORP.
  13. Order 31169Case 28627Listed the unit in a pool zone table, 11 wells allowedWHITING OIL AND GAS CORP.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

14 other units share a surveyed well with this one; overlapping units are not additive.