BBakken SubsurfaceNorth Dakota well index

Spacing unit · Dunn County

1,280-acre Bakken spacing unit

T149N R93W sections 14, 23

Spacing unit14 wells allowed · order 33767Mandaree-Bakken

Unit facts

Formation
Bakken
Acres
1,280
Type
Spacing unit
Land described
T149N R93W sections 14, 23
Pool
Mandaree-Bakken
Zone
Zone XVIII
County
Dunn County
Surveyed wells inside
10
Most wells operated by
Devon Energy
Unit id
dsu-faf4b47126f47264a142
Wells allowed by the latest linked order
14
Wells assigned to this unit
9
Pending permits inside
0
Balance under the allowance
+4
First linked order
Jan 8, 2010
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
9.25 two-mile laterals per 1,280 acres
Density drilled so far
8.8 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

MABEL LEVINGS 14-23HBMABEL LEVINGS 14-23HEMABEL LEVINGS 14-23HYMABEL LEVINGS 14-23HXMABEL LEVINGS 14-23HWMABEL LEVINGS 14-23HASKUNK CREEK 23-14HDSKUNK CREEK 23-14HTSKUNK CREEK 23-14 HCTWO SHIELDS BUTTE 4-24-11-1HU1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
MABEL LEVINGS 14-23HBDEVON ENERGY WILLISTON, L.L.C.Active (A)10,130 ft100%
MABEL LEVINGS 14-23HEDEVON ENERGY WILLISTON, L.L.C.Active (A)10,125 ft100%
MABEL LEVINGS 14-23HYDEVON ENERGY WILLISTON, L.L.C.Active (A)10,053 ft100%
MABEL LEVINGS 14-23HXDEVON ENERGY WILLISTON, L.L.C.Active (A)10,000 ft100%
MABEL LEVINGS 14-23HWDEVON ENERGY WILLISTON, L.L.C.Active (A)9,999 ft100%
MABEL LEVINGS 14-23HADEVON ENERGY WILLISTON, L.L.C.Active (A)9,953 ft100%
SKUNK CREEK 23-14HDDEVON ENERGY WILLISTON, L.L.C.Active (A)9,854 ft100%
SKUNK CREEK 23-14HTDEVON ENERGY WILLISTON, L.L.C.Active (A)9,842 ft100%
SKUNK CREEK 23-14 HCDEVON ENERGY WILLISTON, L.L.C.Active (A)9,212 ft100%
TWO SHIELDS BUTTE 4-24-11-1HUDEVON ENERGY WILLISTON, L.L.C.Active (A)3,599 ft74%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 13964Case 11797Designated the spacing unitPEAK ND, LLC
  2. Order 13965Case 11798Established the spacing unit, 1 well allowedPEAK ND, LLC
  3. Order 14139Case 11951Established the spacing unitZENERGY OPERATING CO., LLC
  4. Order 17495Case 15250Pooled all interests in the unitDAKOTA-3 E&P CO., LLC
  5. Order 18235Case 15973Designated the spacing unitDAKOTA-3 E&P CO., LLC
  6. Order 18499Case 16233Established the spacing unit, 7 wells allowedDAKOTA-3 E&P COMPANY, LLC
  7. Order 23841Case 21499Designated the spacing unit, 14 wells allowedWPX ENERGY WILLISTON, LLC
  8. Order 23885Case 21543Established the spacing unit, 14 wells allowedWPX ENERGY WILLISTON, LLC

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

8 other units share a surveyed well with this one; overlapping units are not additive.