BBakken SubsurfaceNorth Dakota well index

Spacing unit · Dunn County

1,280-acre Bakken spacing unit

T148N R96W sections 8, 17

Spacing unit12 wells allowed · order 35872Lost Bridge-Bakken

Unit facts

Formation
Bakken
Acres
1,280
Type
Spacing unit
Land described
T148N R96W sections 8, 17
Pool
Lost Bridge-Bakken
Zone
Zone XIII
County
Dunn County
Surveyed wells inside
13
Most wells operated by
XTO Energy
Unit id
dsu-07a698587266e0a80ba0
Wells allowed by the latest linked order
12
Wells assigned to this unit
12
Pending permits inside
0
Balance under the allowance
-1
First linked order
May 23, 2008
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
10.74 two-mile laterals per 1,280 acres
Density drilled so far
12.01 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

NYGAARD FEDERAL 13X-5BXCNYGAARD FEDERAL 13X-5EXHTHELMA FEDERAL 11X-20NYGAARD FEDERAL 13X-5F2NYGAARD FEDERAL 13X-5BNYGAARD FEDERAL 13X-5EJORGENSON FEDERAL 44X-5CJORGENSON FEDERAL 44X-5HJORGENSON FEDERAL 44X-5DJORGENSON FEDERAL 44X-5FXGJORGENSON FEDERAL 44X-5G2NYGAARD FEDERAL 13X-5AROBERT FEDERAL 11X-201 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
NYGAARD FEDERAL 13X-5BXCXTO ENERGY INCActive (A)10,520 ft97%
NYGAARD FEDERAL 13X-5EXHXTO ENERGY INCActive (A)10,506 ft98%
NYGAARD FEDERAL 13X-5F2XTO ENERGY INCActive (A)10,480 ft97%
THELMA FEDERAL 11X-20XTO ENERGY INCActive (A)10,480 ft100%
NYGAARD FEDERAL 13X-5BXTO ENERGY INCActive (A)10,457 ft96%
NYGAARD FEDERAL 13X-5EXTO ENERGY INCActive (A)10,450 ft98%
JORGENSON FEDERAL 44X-5CXTO ENERGY INCActive (A)10,442 ft100%
JORGENSON FEDERAL 44X-5HXTO ENERGY INCActive (A)10,305 ft100%
JORGENSON FEDERAL 44X-5DXTO ENERGY INCActive (A)10,254 ft100%
JORGENSON FEDERAL 44X-5FXGXTO ENERGY INCActive (A)10,253 ft100%
JORGENSON FEDERAL 44X-5G2XTO ENERGY INCActive (A)10,207 ft100%
NYGAARD FEDERAL 13X-5AXTO ENERGY INCActive (A)10,153 ft95%
ROBERT FEDERAL 11X-20XTO ENERGY INCPlugged and abandoned (PA)672 ft6%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 11886Case 10072Established the spacing unitHEADINGTON OIL CO. LLC
  2. Order 12356Case 10215Designated the spacing unit
  3. Order 13371Case 11275Designated the spacing unitXTO ENERGY INC.
  4. Order 13857Case 11702Established the spacing unitXTO ENERGY INC.
  5. Order 14072Case 11885Designated the spacing unit, 2 wells allowedENCORE OPERATING, L.P.
  6. Order 14598Case 12346Established the spacing unit, 3 wells allowedXTO ENERGY INC.
  7. Order 18257Case 15994Designated the spacing unit, 8 wells allowedDENBURY ONSHORE, LLC
  8. Order 21013Case 18711Established the spacing unit, 8 wells allowedXTO ENERGY INC.
  9. Order 26927Case 24561Designated the spacing unit, 12 wells allowedXTO ENERGY INC.
  10. Order 27024Case 24660Established the spacing unit, 12 wells allowedXTO ENERGY INC.
  11. Order 27646Case 25227Pooled all interests in the unitXTO ENERGY INC.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

8 other units share a surveyed well with this one; overlapping units are not additive.