BBakken SubsurfaceNorth Dakota well index

Spacing unit · Dunn County

2,560-acre Bakken spacing unit

Footprint 70472a98

Spacing unit

Unit facts

Formation
Bakken
Acres
2,560
Type
Spacing unit
County
Dunn County
Surveyed wells inside
14
Most wells operated by
XTO ENERGY INC
Unit id
dsu-70472a9807ae31e4446e
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
10.7 two-mile laterals per 1,280 acres
Density drilled so far
5.62 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

BANG FEDERAL 21X-19ABANG FEDERAL 21X-19E2FENTON FEDERAL 11X-20BANG FEDERAL 21X-19FBANG FEDERAL 21X-19AXBROBERT FEDERAL 11X-20GEORGE FEDERAL 21X-19ENYGAARD FEDERAL 13X-5AXDGEORGE FEDERAL 21X-19AGEORGE FEDERAL 21X-19F2GEORGE FEDERAL 21X-19BELAINE FEDERAL 12X-19LOIS FEDERAL 24X-6ALWIN FEDERAL 12X-191 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
BANG FEDERAL 21X-19AXTO ENERGY INCActive (A)11,730 ft100%
BANG FEDERAL 21X-19E2XTO ENERGY INCActive (A)11,235 ft100%
FENTON FEDERAL 11X-20XTO ENERGY INCActive (A)11,048 ft94%
BANG FEDERAL 21X-19FXTO ENERGY INCActive (A)10,973 ft100%
BANG FEDERAL 21X-19AXBXTO ENERGY INCActive (A)10,969 ft100%
ROBERT FEDERAL 11X-20XTO ENERGY INCPlugged and abandoned (PA)10,605 ft94%
GEORGE FEDERAL 21X-19EXTO ENERGY INCActive (A)10,092 ft100%
NYGAARD FEDERAL 13X-5AXDXTO ENERGY INCActive (A)10,042 ft94%
GEORGE FEDERAL 21X-19AXTO ENERGY INCActive (A)9,196 ft100%
GEORGE FEDERAL 21X-19F2XTO ENERGY INCActive (A)9,096 ft100%
GEORGE FEDERAL 21X-19BXTO ENERGY INCActive (A)8,708 ft100%
ELAINE FEDERAL 12X-19XTO ENERGY INCActive (A)1,650 ft11%
LOIS FEDERAL 24X-6XTO ENERGY INCActive (A)921 ft7%
ALWIN FEDERAL 12X-19XTO ENERGY INCActive (A)700 ft6%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

No order in the research snapshot has been matched to this footprint yet.

Overlapping units

19 other units share a surveyed well with this one; overlapping units are not additive.