Spacing unit · Dunn County
3,840-acre Bakken spacing unit
T146N R97W section 36
Unit facts
- Formation
- Bakken
- Acres
- 3,840
- Type
- Spacing unit
- Land described
- T146N R97W section 36
- Pool
- Jim Creek-Bakken
- Zone
- Zone XVII
- County
- Dunn County
- Surveyed wells inside
- 23
- Most wells operated by
- Chord / Enerplus / Oasis / Whiting
- Unit id
dsu-20517ab55c6cc52c0a44- Wells allowed by the latest linked order
- 2
- Wells assigned to this unit
- 0
- Pending permits inside
- 0
- Balance under the allowance
- -21
- First linked order
- Sep 22, 2023
- Laterals that still fit (Nov 2026 method)
- 0
- Neighbourhood target density
- 10.72 two-mile laterals per 1,280 acres
- Density drilled so far
- 6.29 per 1,280 acres
Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.
Map
DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.
Wells inside the unit
| Well | Operator | Status | Lateral inside |
|---|---|---|---|
| Benner 3-7H | CONTINENTAL RESOURCES, INC. | Active (A) | 15,515 ft100% |
| Benner 4-7H | CONTINENTAL RESOURCES, INC. | Active (A) | 15,509 ft100% |
| Benner 2-7HSL | CONTINENTAL RESOURCES, INC. | Active (A) | 15,499 ft100% |
| Benner 5-7H | CONTINENTAL RESOURCES, INC. | Active (A) | 15,483 ft100% |
| DANIELLE 145-97-12-1-6H | ENERPLUS RESOURCES USA CORPORATION | Active (A) | 10,650 ft100% |
| BENNER 1-6H | CONTINENTAL RESOURCES, INC. | Active (A) | 10,535 ft100% |
| DANIELLE 145-97-12-1-5H | ENERPLUS RESOURCES USA CORPORATION | Active (A) | 10,450 ft100% |
| Micahlucas 3-5HSL | CONTINENTAL RESOURCES, INC. | Active (A) | 10,358 ft67% |
| DANIELLE 145-97-12-1-7H | ENERPLUS RESOURCES USA CORPORATION | Active (A) | 10,217 ft100% |
| DANIELLE 145-97-12-1-4H | ENERPLUS RESOURCES USA CORPORATION | Active (A) | 10,213 ft100% |
| DANIELLE 145-97-12-1-8H | ENERPLUS RESOURCES USA CORPORATION | Active (A) | 10,205 ft100% |
| DANIELLE 145-97-12-1-3H | ENERPLUS RESOURCES USA CORPORATION | Active (A) | 10,197 ft100% |
| DANIELLE 12-1H | ENERPLUS RESOURCES USA CORPORATION | Active (A) | 9,852 ft100% |
| LK-TROTTER- 146-97-3625H-2 | ENERPLUS RESOURCES USA CORPORATION | Active (A) | 5,171 ft51% |
| Sloan 3-18HSL | CONTINENTAL RESOURCES, INC. | Active (A) | 5,077 ft50% |
| GRANDE 1-18H | CONTINENTAL RESOURCES, INC. | Active (A) | 5,000 ft48% |
| LK-TROTTER- 146-97-3625H-3 | ENERPLUS RESOURCES USA CORPORATION | Active (A) | 4,985 ft50% |
| TROTTER 25-1H | ENERPLUS RESOURCES USA CORPORATION | Active (A) | 4,778 ft52% |
| LK-TROTTER-146-97- 3625H-5 | ENERPLUS RESOURCES USA CORPORATION | Active (A) | 4,620 ft48% |
| LK-TROTTER-146-97- 3625H-4 | ENERPLUS RESOURCES USA CORPORATION | Active (A) | 4,561 ft50% |
| HAMILTON 146-97-35-26-8H-ELL | ENERPLUS RESOURCES USA CORPORATION | Active (A) | 4,136 ft40% |
| DANIELLE 145-97-12-1-2H-WLL | ENERPLUS RESOURCES USA CORPORATION | Active (A) | 2,579 ft25% |
| Eclipse SWD | CONTINENTAL RESOURCES, INC. | Active (A) | 1,768 ft100% |
Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.
Order history
- Order 32695Case 30085Established the spacing unit, 2 wells allowedCONTINENTAL RESOURCES, INC.
- Order 32711Case 30101Pooled all interests in the unitCONTINENTAL RESOURCES, INC.
Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.
Overlapping units
17 other units share a surveyed well with this one; overlapping units are not additive.
- T146N R97W sections 25, 26, 35, 36 2,560-acre Bakken spacing unit
- T146N R97W sections 13, 24, 25 3,840-acre Bakken spacing unit
- T145N R96W sections 7, 18 1,280-acre Bakken spacing unit
- T146N R96W section 31 1,920-acre Bakken spacing unit
- T145N R97W sections 2, 11 1,280-acre Bakken spacing unit
- T145N R97W sections 2, 3, 10, 11 2,560-acre Bakken spacing unit
- T146N R97W sections 25, 36 1,280-acre Bakken spacing unit
- T146N R96W section 31 1,280-acre Bakken spacing unit
- T145N R96W sections 7, 8, 17, 18 2,560-acre Bakken spacing unit
- T146N R96W sections 29, 30, 31, 32 3,840-acre Bakken spacing unit
- T145N R96W sections 18, 19, 30 1,920-acre Bakken spacing unit
- T146N R96W sections 19, 30 1,280-acre Bakken spacing unit
- T146N R97W sections 26, 27, 34, 35 2,560-acre Bakken spacing unit
- T146N R97W sections 26, 35 1,280-acre Bakken spacing unit
- T145N R97W sections 1, 2, 11, 12 2,560-acre Bakken spacing unit
- T145N R97W sections 13, 24, 25 3,840-acre Bakken spacing unit
- T145N R97W sections 1, 12 1,280-acre Bakken spacing unit