Spacing unit · Dunn County
2,560-acre Bakken spacing unit
T145N R96W sections 7, 8, 17, 18
Unit facts
- Formation
- Bakken
- Acres
- 2,560
- Type
- Spacing unit
- Land described
- T145N R96W sections 7, 8, 17, 18
- Pool
- Jim Creek-Bakken
- Zone
- Zone XII
- County
- Dunn County
- Surveyed wells inside
- 17
- Most wells operated by
- CONTINENTAL RESOURCES, INC.
- Unit id
dsu-7547d3fa02924e83d4d2- Laterals that still fit (Nov 2026 method)
- 0
- Neighbourhood target density
- 10.07 two-mile laterals per 1,280 acres
- Density drilled so far
- 6.21 per 1,280 acres
Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.
Map
DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.
Wells inside the unit
| Well | Operator | Status | Lateral inside |
|---|---|---|---|
| SLOAN 1-17H | CONTINENTAL RESOURCES, INC. | Active (A) | 17,268 ft100% |
| GRANDE 1-18H | CONTINENTAL RESOURCES, INC. | Active (A) | 10,457 ft100% |
| Sloan 3-18HSL | CONTINENTAL RESOURCES, INC. | Active (A) | 10,249 ft100% |
| Sloan 7-8H | CONTINENTAL RESOURCES, INC. | Active (A) | 9,957 ft100% |
| Sloan 4-8H | CONTINENTAL RESOURCES, INC. | Active (A) | 9,868 ft100% |
| Sloan 5-8H | CONTINENTAL RESOURCES, INC. | Active (A) | 9,837 ft100% |
| Sloan 6-8H | CONTINENTAL RESOURCES, INC. | Active (A) | 9,806 ft100% |
| SLOAN 2-17H | CONTINENTAL RESOURCES, INC. | Active (A) | 9,605 ft100% |
| Chase 5-18H | CONTINENTAL RESOURCES, INC. | Active (A) | 5,201 ft33% |
| Chase 2-18HSL | CONTINENTAL RESOURCES, INC. | Active (A) | 5,187 ft33% |
| Benner 3-7H | CONTINENTAL RESOURCES, INC. | Active (A) | 5,161 ft33% |
| Chase 4-18H | CONTINENTAL RESOURCES, INC. | Active (A) | 5,154 ft33% |
| Benner 2-7HSL | CONTINENTAL RESOURCES, INC. | Active (A) | 5,147 ft33% |
| Benner 4-7H | CONTINENTAL RESOURCES, INC. | Active (A) | 5,137 ft33% |
| Benner 5-7H | CONTINENTAL RESOURCES, INC. | Active (A) | 5,109 ft33% |
| Chase 3-18H | CONTINENTAL RESOURCES, INC. | Active (A) | 5,108 ft33% |
| DUTCH TREAT 14-8 1 | ANADARKO E&P ONSHORE LLC | Plugged and abandoned (PA) | 2,181 ft100% |
Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.
Order history
- Order 32695Case 30085Established the spacing unitCONTINENTAL RESOURCES, INC.
- Order 32909Case 30299Designated the spacing unitCONTINENTAL RESOURCES, INC.
- Order 32709Case 30099Pooled all interests in the unitCONTINENTAL RESOURCES, INC.
- Order 34301Case 31569Designated the spacing unitBURLINGTON RESOURCES OIL AND GAS CO. LP
Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.
Overlapping units
11 other units share a surveyed well with this one; overlapping units are not additive.
- T146N R97W section 36 3,840-acre Bakken spacing unit
- T145N R96W sections 7, 18 1,280-acre Bakken spacing unit
- T146N R96W section 31 1,920-acre Bakken spacing unit
- T145N R96W sections 19, 20, 29, 30, 31, 32 3,840-acre Bakken spacing unit
- T146N R96W section 31 1,280-acre Bakken spacing unit
- T145N R96W sections 19, 30 1,280-acre Bakken spacing unit
- T145N R96W sections 8, 17 1,280-acre Bakken spacing unit
- T146N R96W sections 29, 30, 31, 32 3,840-acre Bakken spacing unit
- T145N R96W sections 18, 19, 30 1,920-acre Bakken spacing unit
- T145N R97W sections 13, 24, 25 3,840-acre Bakken spacing unit
- T145N R96W sections 8, 9, 16, 17 2,560-acre Bakken spacing unit