BBakken SubsurfaceNorth Dakota well index

Spacing unit · McKenzie County

1,280-acre Bakken spacing unit

T152N R96W sections 29, 32

Spacing unit13 wells allowed · order 33063Westberg-Bakken

Unit facts

Formation
Bakken
Acres
1,280
Type
Spacing unit
Land described
T152N R96W sections 29, 32
Pool
Westberg-Bakken
Zone
Zone IX
County
McKenzie County
Surveyed wells inside
17
Most wells operated by
Devon Energy
Unit id
dsu-5e86a06ae71c8929aae6
Wells allowed by the latest linked order
13
Wells assigned to this unit
12
Pending permits inside
0
Balance under the allowance
-4
First linked order
May 30, 2012
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
10.17 two-mile laterals per 1,280 acres
Density drilled so far
13.19 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

ROLFSRUD 152-96-29-32-7HLWROLFSRUD 152-96-32-29-15HROLFSRUD 152-96-32-29-16HROLFSRUD STATE 152-96-29-32-10HROLFSRUD 152-96-32-29-4HROLFSRUD 152-96-32-29-5HROLFSRUD 152-96-29-32-14HROLFSRUD STATE 152-96-29-32-11HROLFSRUD STATE 152-96-29-32-12HROLFSRUD STATE 152-96-29-32-1HROLFSRUD STATE 152-96-29-32-2HZROLFSRUD STATE 152-96-29-32-3HXROLFSRUD 1-32HROLFSRUD STATE 152-96-29-32-13HLWROLFSRUD 152-96-32-2HROLFSRUD 1-29HOLSON 152-96-30-31-13HLW1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
ROLFSRUD 152-96-29-32-7HLWDEVON ENERGY WILLISTON, L.L.C.Active (A)12,871 ft100%
ROLFSRUD 152-96-32-29-15HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,880 ft100%
ROLFSRUD 152-96-32-29-16HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,499 ft100%
ROLFSRUD STATE 152-96-29-32-10HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,211 ft100%
ROLFSRUD 152-96-32-29-4HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,142 ft100%
ROLFSRUD 152-96-32-29-5HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,142 ft100%
ROLFSRUD 152-96-29-32-14HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,122 ft100%
ROLFSRUD STATE 152-96-29-32-11HDEVON ENERGY WILLISTON, L.L.C.Abandoned (AB)9,974 ft100%
ROLFSRUD STATE 152-96-29-32-12HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,749 ft100%
ROLFSRUD STATE 152-96-29-32-1HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,105 ft100%
ROLFSRUD STATE 152-96-29-32-2HZDEVON ENERGY WILLISTON, L.L.C.Active (A)8,360 ft100%
ROLFSRUD STATE 152-96-29-32-3HXDEVON ENERGY WILLISTON, L.L.C.Active (A)6,801 ft100%
ROLFSRUD 1-32HDEVON ENERGY WILLISTON, L.L.C.Inactive (IA)5,695 ft100%
ROLFSRUD STATE 152-96-29-32-13HLWDEVON ENERGY WILLISTON, L.L.C.Active (A)5,162 ft50%
ROLFSRUD 152-96-32-2HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,321 ft100%
ROLFSRUD 1-29HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,220 ft100%
OLSON 152-96-30-31-13HLWDEVON ENERGY WILLISTON, L.L.C.Active (A)1,216 ft12%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 18840Case 16574Designated the spacing unit, 6 wells allowedNEWFIELD PRODUCTION CO.
  2. Order 19037Case 16768Established the spacing unit, 6 wells allowedNEWFIELD PRODUCTION CO
  3. Order 22849Case 20543Pooled all interests in the unitNEWFIELD PRODUCTION CO.
  4. Order 31199Case 28656Designated the spacing unit, 12 wells allowedOVINTIV PRODUCTION INC.
  5. Order 31200Case 28657Established the spacing unit, 12 wells allowedOVINTIV PRODUCTION INC.
  6. Order 31992Case 29421Established the spacing unit, 13 wells allowedOVINTIV PRODUCTION INC.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

10 other units share a surveyed well with this one; overlapping units are not additive.