BBakken SubsurfaceNorth Dakota well index

Spacing unit · McKenzie County

1,920-acre Bakken spacing unit

T153N R95W sections 7, 17, 18

Spacing unit4 wells allowed · order 32737Charlson-Bakken

Unit facts

Formation
Bakken
Acres
1,920
Type
Spacing unit
Land described
T153N R95W sections 7, 17, 18
Pool
Charlson-Bakken
Zone
Zone XXIII
County
McKenzie County
Surveyed wells inside
19
Most wells operated by
Petro-Hunt
Unit id
dsu-82de5fe7e23c2f902908
Wells allowed by the latest linked order
4
Wells assigned to this unit
4
Pending permits inside
0
Balance under the allowance
-15
First linked order
Jul 11, 2013
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
10.12 two-mile laterals per 1,280 acres
Density drilled so far
6.87 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. 4 more would fit the density but not the spacing rule. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

KLEVMOEN TRUST 153-95-17D-7-4HKLEVMOEN TRUST 153-95-17D-7-3HKLEVMOEN 153-95-17C-7- 2HKLEVMOEN 153-95-17C-7- 1HState 153-95-17B-16- 1HUSA 153-95-18B-4HKLEVMOEN TRUST 17D-4-3HTHOMPSON 153-95-8C-6-5HUSA 153-95-18B-2HUSA 153-95-7C-31-1HSUSA 153-95-18B-1HL.M. THOMPSON 7D-4-4HState 153-95-17B-16- 2HUSA 153-95-18C- 3HState 153-95-17B-16- 3HTHOMPSON 153-95-8C-6-4HTHOMPSON 153-95-8D-6-3HTHOMPSON FEDERAL 41X-17-TF2THOMPSON 41X-17MB31 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
KLEVMOEN TRUST 153-95-17D-7-4HPETRO-HUNT, L.L.C.Active (A)12,877 ft100%
KLEVMOEN TRUST 153-95-17D-7-3HPETRO-HUNT, L.L.C.Active (A)11,692 ft100%
KLEVMOEN 153-95-17C-7- 2HPETRO-HUNT, L.L.C.Active (A)10,339 ft100%
KLEVMOEN 153-95-17C-7- 1HPETRO-HUNT, L.L.C.Active (A)8,850 ft100%
State 153-95-17B-16- 1HPETRO-HUNT, L.L.C.Active (A)6,416 ft91%
USA 153-95-18B-4HPETRO-HUNT, L.L.C.Active (A)5,995 ft100%
KLEVMOEN TRUST 17D-4-3HPETRO-HUNT, L.L.C.Active (A)5,707 ft100%
THOMPSON 153-95-8C-6-5HPETRO-HUNT, L.L.C.Active (A)5,159 ft62%
USA 153-95-18B-2HPETRO-HUNT, L.L.C.Active (A)5,055 ft100%
USA 153-95-7C-31-1HSPETRO-HUNT, L.L.C.Active (A)4,997 ft32%
USA 153-95-18B-1HPETRO-HUNT, L.L.C.Active (A)4,862 ft100%
L.M. THOMPSON 7D-4-4HPETRO-HUNT, L.L.C.Active (A)4,844 ft100%
State 153-95-17B-16- 2HPETRO-HUNT, L.L.C.Active (A)4,667 ft70%
USA 153-95-18C- 3HPETRO-HUNT, L.L.C.Active (A)4,629 ft100%
State 153-95-17B-16- 3HPETRO-HUNT, L.L.C.Active (A)3,595 ft52%
THOMPSON 153-95-8C-6-4HPETRO-HUNT, L.L.C.Active (A)3,362 ft34%
THOMPSON 153-95-8D-6-3HPETRO-HUNT, L.L.C.Active (A)2,790 ft22%
THOMPSON FEDERAL 41X-17-TF2XTO ENERGY INCActive (A)1,392 ft25%
THOMPSON 41X-17MB3XTO ENERGY INCActive (A)865 ft13%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 21095Case 18793Established the spacing unit, 1 well allowedPETRO- HUNT, LLC
  2. Order 21095Case 18793Designated the spacing unitPETRO- HUNT, LLC
  3. Order 22329Case 20024Established the spacing unit, 2 wells allowedPETRO- HUNT, LLC
  4. Order 25487Case 23156Designated the spacing unitXTO ENERGY INC.
  5. Order 26084Case 23742Designated the spacing unit, 4 wells allowedXTO ENERGY INC.
  6. Order 26825Case 24459Established the spacing unit, 4 wells allowedPETRO- HUNT, L.L.C.
  7. Order 29198Case 26762Pooled all interests in the unitPETRO- HUNT, L.L.C.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

21 other units share a surveyed well with this one; overlapping units are not additive.