BBakken SubsurfaceNorth Dakota well index

Spacing unit · McKenzie County

3,840-acre Bakken spacing unit

T153N R95W sections 3, 4, 9, 10, 15, 16

Spacing unit4 wells allowed · order 32737Charlson-Bakken

Unit facts

Formation
Bakken
Acres
3,840
Type
Spacing unit
Land described
T153N R95W sections 3, 4, 9, 10, 15, 16
Pool
Charlson-Bakken
Zone
Zone XXXIII
County
McKenzie County
Surveyed wells inside
38
Most wells operated by
Petro-Hunt
Unit id
dsu-86c31410d225faf2d285
Wells allowed by the latest linked order
4
Wells assigned to this unit
1
Pending permits inside
0
Balance under the allowance
-33
First linked order
Apr 9, 2014
Laterals that still fit (Nov 2026 method)
1 (1.45 two-mile equivalents)
Neighbourhood target density
10.32 two-mile laterals per 1,280 acres
Density drilled so far
7.69 per 1,280 acres

Room to drill: 1 lateral still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. 1 more would fit the density but not the spacing rule. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

USA 153-95-3B-10- 2HUSA 153-95-9C-4-3HUSA 153-95-4B-9-4HUSA 153-95-4B-9-5HUSA 153-95-4A-9-7HUSA 153-95-4A-9-6HUSA 153-95-4A-9-8HUSA 153-95-3B-10- 1HUSA 153-95-4B-9-1HUSA 153-95-9A-15-1HSUSA 153-95-4B-9-1HSUSA 153-95-3B-10- 3HUSA 153-95-3A-10- 4HUSA 153-95-3D-10-5HUSA 153-95-3D-10-6HUSA 153-95-9A-4-1HSUSA 153-95-3A-33 1HUSA 153-95-22C-15-2HTHOMPSON 41X-17MB3STATE 11-16HUSA 153-95-22C-15-6HUSA 153-95-22D-15-1HSUSA 153-95-22D-15-5HUSA 153-95-22C-15-3HUSA 153-95-22D-15-4HUSA 153-95-22C-15-1HUSA 3D-4-4HSTATE 11X-16MB5USA 10B-2-4HUSA 153-95-3A-33 2HSTATE 11X-16TF4STATE 11X-16MB4THOMPSON FEDERAL 41X-17-TF2State 153-95-17B-16- 3HUSA 153-95-3A-33 3HState 153-95-17B-16- 2HCHARLSON MADISON NORTH UNIT D234XHUSA 153-95-3A-33 4H1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
USA 153-95-3B-10- 2HPETRO-HUNT, L.L.C.Active (A)12,382 ft100%
USA 153-95-9C-4-3HPETRO-HUNT, L.L.C.Active (A)10,521 ft100%
USA 153-95-4B-9-4HPETRO-HUNT, L.L.C.Active (A)10,397 ft100%
USA 153-95-4B-9-5HPETRO-HUNT, L.L.C.Active (A)10,374 ft100%
USA 153-95-4A-9-7HPETRO-HUNT, L.L.C.Active (A)10,338 ft100%
USA 153-95-4A-9-6HPETRO-HUNT, L.L.C.Active (A)10,284 ft100%
USA 153-95-4A-9-8HPETRO-HUNT, L.L.C.Active (A)10,280 ft100%
USA 153-95-3B-10- 1HPETRO-HUNT, L.L.C.Active (A)9,867 ft100%
USA 153-95-4B-9-1HPETRO-HUNT, L.L.C.Active (A)9,672 ft100%
USA 153-95-9A-15-1HSPETRO-HUNT, L.L.C.Active (A)9,523 ft100%
USA 153-95-4B-9-1HSPETRO-HUNT, L.L.C.Active (A)9,412 ft100%
USA 153-95-3B-10- 3HPETRO-HUNT, L.L.C.Active (A)8,679 ft100%
USA 153-95-3A-10- 4HPETRO-HUNT, L.L.C.Active (A)8,053 ft100%
USA 153-95-3D-10-5HPETRO-HUNT, L.L.C.Active (A)6,749 ft100%
USA 153-95-3D-10-6HPETRO-HUNT, L.L.C.Active (A)6,531 ft100%
USA 153-95-9A-4-1HSPETRO-HUNT, L.L.C.Active (A)5,897 ft100%
USA 153-95-3A-33 1HPETRO-HUNT, L.L.C.Active (A)5,756 ft45%
USA 153-95-22C-15-2HPETRO-HUNT, L.L.C.Active (A)5,605 ft54%
THOMPSON 41X-17MB3XTO ENERGY INCActive (A)5,584 ft87%
STATE 11-16HXTO ENERGY INCActive (A)5,280 ft100%
USA 153-95-22C-15-6HPETRO-HUNT, L.L.C.Active (A)5,196 ft52%
USA 153-95-22D-15-1HSPETRO-HUNT, L.L.C.Active (A)5,061 ft50%
USA 153-95-22D-15-5HPETRO-HUNT, L.L.C.Active (A)5,051 ft53%
USA 153-95-22C-15-3HPETRO-HUNT, L.L.C.Active (A)5,046 ft52%
USA 153-95-22D-15-4HPETRO-HUNT, L.L.C.Active (A)5,045 ft52%
USA 153-95-22C-15-1HPETRO-HUNT, L.L.C.Active (A)5,040 ft53%
USA 3D-4-4HPETRO-HUNT, L.L.C.Active (A)4,772 ft100%
STATE 11X-16MB5XTO ENERGY INCActive (A)4,727 ft100%
USA 10B-2-4HPETRO-HUNT, L.L.C.Abandoned (AB)4,591 ft100%
USA 153-95-3A-33 2HPETRO-HUNT, L.L.C.Active (A)4,495 ft39%
STATE 11X-16TF4XTO ENERGY INCActive (A)4,334 ft100%
STATE 11X-16MB4XTO ENERGY INCActive (A)4,292 ft100%
THOMPSON FEDERAL 41X-17-TF2XTO ENERGY INCActive (A)4,123 ft75%
State 153-95-17B-16- 3HPETRO-HUNT, L.L.C.Active (A)3,287 ft48%
USA 153-95-3A-33 3HPETRO-HUNT, L.L.C.Active (A)2,876 ft28%
State 153-95-17B-16- 2HPETRO-HUNT, L.L.C.Active (A)1,958 ft30%
CHARLSON MADISON NORTH UNIT D234XHPETRO-HUNT, L.L.C.Plugged and abandoned (PA)1,539 ft63%
USA 153-95-3A-33 4HPETRO-HUNT, L.L.C.Active (A)1,388 ft16%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 22329Case 20024Established the spacing unit, 2 wells allowedPETRO- HUNT, LLC
  2. Order 24140Case 21811Designated the spacing unit, 4 wells allowedPETRO- HUNT, LLC
  3. Order 24141Case 21812Established the spacing unit, 4 wells allowedPETRO- HUNT, LLC
  4. Order 28948Case 26515Pooled all interests in the unitPETRO- HUNT, L.L.C.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

23 other units share a surveyed well with this one; overlapping units are not additive.