BBakken SubsurfaceNorth Dakota well index

Spacing unit · McKenzie County

2,560-acre Bakken spacing unit

T153N R95W sections 8, 9, 16, 17

Spacing unit2 wells allowed · order 32737Charlson-Bakken

Unit facts

Formation
Bakken
Acres
2,560
Type
Spacing unit
Land described
T153N R95W sections 8, 9, 16, 17
Pool
Charlson-Bakken
Zone
Zone XXVIII
County
McKenzie County
Surveyed wells inside
33
Most wells operated by
Petro-Hunt
Unit id
dsu-aefb138895dd7e7c70e8
Wells allowed by the latest linked order
2
Wells assigned to this unit
1
Pending permits inside
0
Balance under the allowance
-31
First linked order
Aug 13, 2014
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
10.19 two-mile laterals per 1,280 acres
Density drilled so far
7.85 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. 2 more would fit the density but not the spacing rule. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

USA 153-95-9A-15-1HSTHOMPSON 153-95-8D-6-2HState 153-95-17B-16- 1HState 153-95-17B-16- 3HState 153-95-17B-16- 2HTHOMPSON 41X-17MB3THOMPSON 8D-4-4HKLEVMOEN TRUST 17D-4-3HKLEVMOEN TRUST 153-95-17D-7-4HTHOMPSON FEDERAL 41X-17-TF2USA 153-95-9C-4-3HTHOMPSON 153-95-8D-6-3HSTATE 11-16HUSA 153-95-4A-9-7HUSA 153-95-4A-9-6HUSA 153-95-4B-9-5HUSA 153-95-4B-9-4HUSA 153-95-4A-9-8HUSA 153-95-4B-8-2HSUSA 153-95-4B-9-1HSUSA 153-95-4B-9-1HKLEVMOEN TRUST 153-95-17D-7-3HSTATE 11X-16MB5USA 153-95-8A-31-4HSTATE 11X-16TF4STATE 11X-16MB4KLEVMOEN 153-95-17C-7- 2HUSA 153-95-8A-31- 3HTHOMPSON 153-95-8C-6-4HKLEVMOEN 153-95-17C-7- 1HUSA 153-95-8A-31- 2HTHOMPSON 153-95-8C-6-5HUSA 153-95-9A-4-1HS1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
USA 153-95-9A-15-1HSPETRO-HUNT, L.L.C.Active (A)9,463 ft99%
THOMPSON 153-95-8D-6-2HPETRO-HUNT, L.L.C.Active (A)8,587 ft52%
State 153-95-17B-16- 1HPETRO-HUNT, L.L.C.Active (A)7,019 ft100%
State 153-95-17B-16- 3HPETRO-HUNT, L.L.C.Active (A)6,881 ft100%
State 153-95-17B-16- 2HPETRO-HUNT, L.L.C.Active (A)6,626 ft100%
THOMPSON 41X-17MB3XTO ENERGY INCActive (A)6,450 ft100%
THOMPSON 8D-4-4HPETRO-HUNT, L.L.C.Active (A)5,936 ft100%
KLEVMOEN TRUST 17D-4-3HPETRO-HUNT, L.L.C.Active (A)5,707 ft100%
KLEVMOEN TRUST 153-95-17D-7-4HPETRO-HUNT, L.L.C.Active (A)5,621 ft44%
THOMPSON FEDERAL 41X-17-TF2XTO ENERGY INCActive (A)5,515 ft100%
USA 153-95-9C-4-3HPETRO-HUNT, L.L.C.Active (A)5,494 ft52%
THOMPSON 153-95-8D-6-3HPETRO-HUNT, L.L.C.Active (A)5,413 ft43%
STATE 11-16HXTO ENERGY INCActive (A)5,280 ft100%
USA 153-95-4A-9-7HPETRO-HUNT, L.L.C.Active (A)5,231 ft51%
USA 153-95-4A-9-6HPETRO-HUNT, L.L.C.Active (A)5,226 ft51%
USA 153-95-4B-9-5HPETRO-HUNT, L.L.C.Active (A)5,222 ft50%
USA 153-95-4B-9-4HPETRO-HUNT, L.L.C.Active (A)5,219 ft50%
USA 153-95-4A-9-8HPETRO-HUNT, L.L.C.Active (A)5,187 ft50%
USA 153-95-4B-8-2HSPETRO-HUNT, L.L.C.Active (A)5,024 ft52%
USA 153-95-4B-9-1HSPETRO-HUNT, L.L.C.Active (A)5,008 ft53%
USA 153-95-4B-9-1HPETRO-HUNT, L.L.C.Active (A)5,003 ft52%
KLEVMOEN TRUST 153-95-17D-7-3HPETRO-HUNT, L.L.C.Active (A)4,868 ft42%
STATE 11X-16MB5XTO ENERGY INCActive (A)4,727 ft100%
USA 153-95-8A-31-4HPETRO-HUNT, L.L.C.Active (A)4,692 ft35%
STATE 11X-16TF4XTO ENERGY INCActive (A)4,334 ft100%
STATE 11X-16MB4XTO ENERGY INCActive (A)4,292 ft100%
KLEVMOEN 153-95-17C-7- 2HPETRO-HUNT, L.L.C.Active (A)3,928 ft38%
USA 153-95-8A-31- 3HPETRO-HUNT, L.L.C.Active (A)3,487 ft22%
THOMPSON 153-95-8C-6-4HPETRO-HUNT, L.L.C.Active (A)2,764 ft28%
KLEVMOEN 153-95-17C-7- 1HPETRO-HUNT, L.L.C.Active (A)2,503 ft28%
USA 153-95-8A-31- 2HPETRO-HUNT, L.L.C.Active (A)1,873 ft14%
THOMPSON 153-95-8C-6-5HPETRO-HUNT, L.L.C.Active (A)1,145 ft14%
USA 153-95-9A-4-1HSPETRO-HUNT, L.L.C.Active (A)723 ft12%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 24140Case 21811Designated the spacing unit, 2 wells allowedPETRO- HUNT, LLC
  2. Order 24143Case 21814Established the spacing unit, 2 wells allowedPETRO- HUNT, LLC

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

23 other units share a surveyed well with this one; overlapping units are not additive.